OM3 50/125 GYXTW Fiilada Fiber-ka ee Dibadda Fiilada Dhexe ee dabacsan ee Dibadda
Astaamaha Farsamada Fiber Optic-ga GYXTW:
| Lambarka faybarka | Dhexroorka fiilada | Miisaanka |
| 1~12 | 8.0mm+-0.3mm | 70kg/km |
| 7.0mm+-0.1mm | 50kg/km | |
| Heerkulka kala duwan | -40°C+70°C | |
| Gacanka Laabista Ugu Yar (mm) | Muddo dheer | 10D |
| Laabista Ugu YarGacanka (mm) | Muddo gaaban | 20D |
| Xoogga Garaacista ee ugu yar ee la oggol yahay (N) | Muddo dheer | 1200 |
| Xoogga Garaacista ee ugu yar ee la oggol yahay (N) | Muddo gaaban | 1500 |
| Heerkulka Hawlgalka | -40°C+70°C | |
| Heerkulka rakibidda | -20°C+60°C | |
| Heerkulka kaydinta | -40°C+70°C | |
Astaanta Faybarka:
| Qaabka Faybarka | Cutubka | MM OM3-300 | |
| xaalad | nm | 850/1300 | |
| hoos u dhac | dB/km | ≤3.0/1.0 | |
| ---- | |||
| Kala Fidsanaan | 1550nm | Ps/(nm*km) | Kala Fidsanaan |
| 1625nm | Ps/(nm*km) | ||
| Ballaca baaxadda | 850nm | MHZ.KM | Ballaca baaxadda |
| 1300nm | MHZ.KM | ||
| Mowjadda kala-fidinta eber | nm | ≧ 1295, ≤1320 | |
| Jiirada kala-fidinta eber | nm | ---- | |
| Fiber-ka Shakhsiga ah ee ugu Badan ee PMD | ≤0.11 | ||
| Qiimaha Isku xirka Naqshadeynta PMD | Ps(nm2*km) | ---- | |
| Mowjadaha dhererka faybarka λc | nm | ---- | |
| Mowjadda goynta fiilada λcc | nm | ---- | |
| MFD | 1310nm | um | ---- |
| 1550nm | um | ---- | |
| Dalool tirooyin ah (NA) | 0.200+/-0.015 | ||
| Tallaabo (celceliska cabbirka laba-jiho) | dB | ≤0.10 | |
| Khaladaadka dhererka iyo barta faybarka | dB | ≤0.10 | |
Midabka faybarka:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Buluug | Liin dhanaan | Cagaaran | Bunni | Cawlan | Caddaan |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Casaan | Madow | Jaalle | Fiyoolet | Casaan | Biyo |
Waa maxay fiilada GYXTW?
•Fiilada fiber optic-ga ee GYXTW, fiilooyinka 250μm, waxay ku jiraan tuubo dabacsan oo laga sameeyay balaastik modulus sare leh.
•Tuubooyinka waxaa ka buuxa isku-darka buuxinta biyaha u adkaysta.
•Tuubada waxaa lagu duubay lakab PSP ah oo dherer ahaan loo sameeyay.
•Inta u dhaxaysa PSP iyo qalabka biyaha ka ilaaliya tuubada dabacsan ayaa la mariyaa si fiilada looga dhigo mid isku xiran oo aan biyuhu geli karin.
•Laba fiilooyin bir ah oo is barbar socda ayaa la dhigayaa labada dhinac ee cajaladda birta ah.
•Fiilada waxaa lagu dhammeeyaa dahaar polyethylene (PE).
•Fiilada OM3 ee fiilada ayaa la sameeyay iyadoo la raacayo heerarka ugu dambeeyay ee 10Gbit waxayna u oggolaanaysaa gudbinta xogta masaafada ugu badan ilaa 300 m oo ah 850 nm. Sababtoo ah astaamaha indhaha ee aadka u fiican, marka laga reebo fiilooyinka caadiga ah ee 600/1200 nm, fiilada OM3 ee fiilada ayaa lagu dabaqi karaa isku xirka laf-dhabarta iyadoo lagu saleynayo tignoolajiyad badan oo kharash-ool ah ilaa 10Gbit.
Dhismaha:
Astaamaha:
•Xubin siman oo bir ah, buuxiye ayaa ilaaliya cajalad bir ah oo fiilada tuubada ah oo la surfacay.
•Waxqabad farsamo iyo deegaan oo heer sare ah.
•Qaab-dhismeedka is haysta, miisaan fudud ayaa si habboon loogu rakibi karaa oo si fudud loogu shaqeyn karaa.
•Fiber kale ayaa la heli karaa ikhtiyaar: Hab keli ah (G652D, G657A, G657B) iyo Multimode (OM1, Om2, Om3, OM4, OM5)
•Tirada faybarka: 2fo ~ 12fo
•Ikhtiyaarka dhexroorka: 6.0mm, 7.0mm (shaqadii hore), 8.0mm
Codsiga:
+ Waxaa loo qaatay qaybinta bannaanka.
+ Ku habboon habka hawo-mareenka, habka gelinta dhuumaha.
+ Isgaarsiinta shabakadda masaafada dheer iyo deegaanka.
Baakad: