12fibers MM OM3-300 MPO-12 Fiilada Balastar-ka ee Indhaha / Fiilada Jirka Fiber-ka ee MTP OM3 12F
Fiilada Balastar-ka ee MM OM3-300 MPO-12 ee Indhaha / Fiilada Jirka Fiber-ka ee MTP OM3 12F
Qaab-dhismeedka Fiilada Jirka: Dhinaca Isku-xirka A + fiilo yar 3.0mm + Dhinaca Isku-xirka B

- Dhinaca Isku-xirka A:
+ MPO-12 Lab / Dheddig
+ MTP-12 Lab / Dheddig
- Fiilo yar 3.0mm:
+ Nooca faybarka: OM3-300
+ Tirada faybarka: 12
+ Dhexroorka fiilada: 3.0mm
+ Midabka fiilada: biyo
+ Dhererka fiilada: la habeeyey
- Dhinaca isku xirka B:
+ MPO-12 Lab / Dheddig
+ MTP-12 Lab / Dheddig
- Heerka IL:
+ Heerka IL: 0.65dB
+ ULL (Elite) IL: 0.35dB
- Kala duwanaanshaha:
+ Nooca A
+ Nooca B
+ Nooca C
Faybarka OM3-150 iyo Faybarka OM3-300
- Fiilada MPO-12 Optical Patch Cable / Fiilada Jirka Fiber MTP OM3 12F waxay isticmaashaa fiilada yar ee 3.0mm OM3-300 si ay u noqoto fiilo weyn, si ay u badbaadiso booska ugu badan marka lagu rakibo qaabka qaybinta fiber optic-ga.
- OM3-150 iyo OM3-300 waa fiber OM3 oo badan, laakiin waxaa jira kala duwanaansho yar oo u dhexeeya.
- OM3-150 waxay taageertaa 10G Ethernet ilaa 150 mitir, halka OM3-300 ay taageerto 10G Ethernet ilaa 300 mitir waxayna bixisaa labanlaab baaxadda waxtarka leh.
+ OM3-150: Tani badanaa waa ikhtiyaar qiimo jaban oo loo isticmaalo isku xiryo aad u gaaban oo ku yaal meel gaar ah ama qol yar oo adeegayaal ah halkaas oo masaafada aysan waligood ka badnayn 150 mitir. Maadaama aysan buuxin heerka caalamiga ah ee OM3 ee 300-mitir oo buuxa, way ka yar tahay oo way ka dabacsan tahay casriyeynta mustaqbalka.
+ OM3-300: Kani waa heerka caalamiga ah ee fiber-ka OM3. Waxaa si ballaaran loogu adeegsadaa xarumaha xogta shirkadaha, qolalka server-ka, iyo laf-dhabarta xerada halkaas oo looga baahan yahay isku-xirro masaafo dhexdhexaad ah. Waxay bixisaa waxqabad la isku halleyn karo oo loogu talagalay isku-xirka 10G, 40G, iyo 100G.
- Furaha kala duwan:
| Muuqaalka | OM3-150 | OM3-300 |
| Gudbinta ugu badan ee 10G | 150 mitir | 300 mitir |
| Bandwidth Modal oo wax ku ool ah | ≥ 950 MHz⋅km | ≥ 2000 MHz⋅km |
| 40G/100G Gaarid | Ilaa 100 mitir | Ilaa 100 mitir |
- Fiilooyinka OM3-150 iyo OM3-300 labaduba si buuxda ayay isu waafaqsan yihiin waxayna isticmaalaan jaakad buluug ah oo isku mid ah.
- Marka aad u baahan tahay inaad ku wareejiso masaafad gaaban dhererka fiilada oo ka yar 150m, waxaad dooran kartaa OM3-150 si aad u badbaadiso kharashka. Marka aad u baahan tahay inaad ku wareejiso masaafad ka dheer 150m iyo 300m gudahood, waa inaad doorataa OM3-300 si aad u hubiso saameynta wareejinta.
Fiilo yar oo 3.0mm ah OM3-300 12F
Isku xira MPO MTP Multimode
- Isku xirka multimode MPO (Multi-Fiber Push-On) waa isku xirka fiber optic-ga oo cufnaan sare leh kaas oo isku daraya fiilooyin badan (badanaa 8, 12, ama 24) hal xiriir.
- MPO waa nooc isku xira fiilooyinka halka MTP ay tahay calaamad ganacsi oo diiwaangashan oo isku xiraha MPO ah oo ay soo saartay US Conec, Senko, ama summad kale.
- MPO waxay u taagan tahay Multi-Fiber Push On. Xidhiidhiyahan waxaa badanaa loo isticmaalaa in lagu joojiyo isku xirka xargaha badan ee fiilooyinka ee jawiga gudaha.
- Isku xirka MPO MTP wuxuu noqon karaa lab ama dheddig.
Dheddig: biin la'aan
Lab: oo leh biin
- Waxaa si weyn loogu isticmaalaa xarumaha xogta, waa mid ku habboon gudbinta isbarbar socda (sida 40G ama 100G Ethernet) iyo fidinta fiilooyinka degdega ah.
Codsiyada
+ FTTx (FTTA, FTTB, FTTC, FTTH, FTTO, iwm)
+ Isku xirka Xarunta Xogta
+ WAN/LAN
+ Qolka xakamaynta saldhigga tareenka xawaaraha sare leh
+ Xarunta xogta AI
+ Xarunta xogta ee isku xirka xiddigaha
+ Xarunta xogta bangiga
Tilmaamaha
| Nooca | Hab Keli ah | Hab Keli ah | Qaab Badan | |||
| (APC Polish) | (UPC Polish) | (Boolishka PC) | ||||
| Tirada Faybarka | 8f, 12f, 16f, 24f, 32f, 48f | 8f, 12f, 16f, 24f, 32f, 48f | 8f, 12f, 16f, 24f, 32f, 48f | |||
| Nooca Faybarka | G657A1, G657A2 | G657A1, G657A2 | OM1, OM2, OM3, OM4, OM5, iwm. | |||
| Lumista ugu Badan ee Gelinta | Elite | Heerka Caadiga ah | Elite | Heerka Caadiga ah | Elite | Heerka Caadiga ah |
| Lumis Aad u Yar | Lumis Aad u Yar | Khasaare Hoose | ||||
| ≤0.35 dB | ≤0.75dB | ≤0.35 dB | ≤0.75dB | ≤0.35 dB | ≤0.60dB | |
| Lumis Soo Celin ah | ≥60 dB | ≥60 dB | NA | |||
| Waara | ≥500 jeer | ≥500 jeer | ≥500 jeer | |||
| Heerkulka Hawlgalka | -40℃~+80℃ | -40℃~+80℃ | -40℃~+80℃ | |||
| Mowjadda Tijaabada | 1310nm | 1310nm | 1310nm | |||
| Tijaabada Gelinta-Jidka | 1000 jeer<0.5 dB | |||||
| Isweydaarsiga | <0.5 dB | |||||
| Xoogga ka hortagga cadaadiska | 15kgf | |||||