KCO-Fiver-MTP-MPO-QSFP-Banner-bogga-1

Fiilada Fiilada Gudaha ee Fiber Optical-ka ah ee Qaybinta ee Fanout Tight Buffer (GJFJV)

Sharaxaad Gaaban:

Fiilada Fiber-ka Gudaha ee Qaybinta ee Fanout Tight Buffer (GJFJV) waxaa loo isticmaalaa fiilooyinka fiilooyinka indhaha iyo fiilooyinka balastarada ee fiber-ka.
Waxaa loo isticmaali jiray sidii khadadka isku xidha qalabka, waxaana loo isticmaali jiray isku xirka indhaha ee qolalka isgaarsiinta indhaha iyo qaababka qaybinta indhaha.
Waa mid weyn oo loo isticmaalo fiilooyinka gudaha, gaar ahaan loo isticmaalo fiilada qaybinta.
Sifooyin farsamo iyo deegaan oo wanaagsan.
Astaamaha dab-damiska ayaa buuxiya shuruudaha heerarka khuseeya.
Astaamaha farsamada ee jacked waxay buuxiyaan shuruudaha heerarka khuseeya.
Fiilada fiilada gudaha ee fiilada leh waa mid jilicsan, dabacsan, si fudud loo dhigi karo loona kala qaybin karo, waxayna leedahay gudbin xog oo awood weyn leh.
Buuxi shuruudaha kala duwan ee suuqa iyo macaamiisha.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Halbeegyada Farsamada:

Fiilada Fiber-ka Gudaha ee Fanout (GJFJV) Dhexroorka fiilada Miisaanka
2 xudunta 4.5mm 22.00kg/km
4 xudunta 4.5mm 22.00kg/km
6 xudunta 4.5mm 23.00kg/km
8 xudunta 5.5mm 27.00kg/km
10 xudunta 5.5mm 30.00kg/km
12 xudunta 6.0mm 35.00kg/km
Heerkulka kaydinta (℃) -20+60
Gacanka Laabista Ugu Yar (mm) Muddo dheer 10D
Gacanka Laabista Ugu Yar (mm) Muddo gaaban 20D
Xoogga Garaacista ee ugu yar ee la oggol yahay (N) Muddo dheer 200
Xoogga Garaacista ee ugu yar ee la oggol yahay (N) Muddo gaaban 600
Culayska Burburinta (N/100mm) Muddo dheer 200
Culayska Burburinta (N/100mm) muddo gaaban 1000

Astaanta Faybarka:

Qaabka Faybarka Cutubka SMG652 SMG652D SMG657A MM50/125 MM62.5/125 MMOM3-300
xaalad nm 1310/1550 1310/1550 1310/625 850/1300 850/1300 850/1300
hoos u dhac dB/km ≤0.36/0.23 ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0
Kala Fidsanaan 1550nm Ps/(nm*km) ---- ≤18 ≤18 ---- ----

----

  1625nm Ps/(nm*km) ---- ≤22 ≤22 ---- ----

----

Ballaca baaxadda 850nm MHZ.KM ---- ----   ≥400 ≥160  
  1300nm MHZ.KM ---- ----   ≥800 ≥500  
Mowjadda kala-fidinta eber nm ≥1302≤1322 ≥1302≤1322 ≥1302≤1322 ---- ---- ≥ 1295,≤1320
Jiirada kala-fidinta eber nm ≤0.092 ≤0.091 ≤0.090 ---- ---- ----
Fiber-ka Shakhsiga ah ee ugu Badan ee PMD   ≤0.2 ≤0.2 ≤0.2 ---- ---- ≤0.11
Qiimaha Isku xirka Naqshadeynta PMD Ps(nm2*km) ≤0.12 ≤0.08 ≤0.1 ---- ---- ----
Mowjadaha dhererka faybarka λc nm ≥ 1180≤1330 1180≤1330 ≥1180≤1330 ---- ---- ----
Xadhkaha fiiladahirarka λcc nm ≤1260 ≤1260 ≤1260 ---- ---- ----
MFD 1310nm um 9.2±0.4 9.2±0.4 9.0±0.4 ---- ---- ----
  1550nm um 10.4±0.8 10.4±0.8 10.1±0.5 ---- ---- ----
Tiro ahaanDalool (NA)   ---- ---- ---- 0.200± 0.015 0.275±0.015 0.200±0.015
Tallaabo (celceliska labada jiho)cabbir) dB ≤0.05 ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10
Khaladaadka ku yimaada faybarkadhererka iyo barta dB ≤0.05 ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10
Joogsi la'aan  
Farqiga u dhexeeya dib-u-soo-kabashadaisku-dhafka dB/km ≤0.05 ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08
Midaysanaan yaraanshaha dB/km ≤0.01 ≤0.01 ≤0.01      
Dhexroorka xudunta um  9  9 9 50±1.0 62.5±2.5 50±1.0
Dhexroorka dahaarka um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
Dahaarka aan wareegsanayn % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
Dhexroorka daahan um 242±7 242±7 242±7 242±7 242±7 242±7
Dahaarka/chaffinchqalad si qotodheer loo sameeyay um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
Dahaarka aan wareegsanayn % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
Qaladka isku-xidhka xudunta/dahaadhka um ≤0.6 ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5
Laablaab (gacan) um ≤4 ≤4 ≤4 ---- ---- ----

Dhismaha Fiilada:

图片 2

Goynta Fiilada:

图片 4

Fiilo 8 xudunta OM3 Multimode ah

图片 3

Fiilo hal qaab ah oo 4 xudunta ah

图片 5

Fiilo 24 xudunta ah oo leh qaab-dhismeed badan 50/125

Sharaxaadaha:

Fiilada Fiber-ka Gudaha ee Qaybinta ee Feeraha Toosan waxay isticmaashaa 2 ~ 48 xudunta (ama ka badan) waxayna isticmaashaa 900 μm ama 600 μm fiilada toosan ee fiilada hoosteeda. Caadiyan waxay daboolaysaa isticmaalka PVC ama LSZH, sidoo kale isticmaal PE ama Nilon.

Faybarka adag ee ku duuban lakab dun aramid ah oo ah xubin xoog leh, ka dibna waxaa lagu dhammaystiray lakab ah walxo PVC ama LSZH ah sida jaakad dibadda ah.

Midabka jaakadda Fiber Indoor Optical ee Qaybinta Fanout Tight Buffer:

Hab keli ah: Jaalle,

Qaab-dhismeed badan OM1 / OM2: Liin,

Qaab-dhismeed badan OM3 / OM4: Biyo,

Qaab-dhismeed badan OM4: Fiyoolat,

Mutimode OM5: Lime.

Midab kale waa ikhtiyaari.

Codsiga:

+ Waxaa loo isticmaalaa dabada iyo fiilooyinka balastarada.

+ Waxaa loo isticmaalaa sidii khadadka isku xidhka qalabka, waxaana loo isticmaalaa isku xirka indhaha ee indhahaqolalka isgaarsiinta, xarunta xogta iyo qaababka qaybinta indhaha.

+ Waxaa loo isticmaalaa fiilooyinka gudaha, gaar ahaan fiilo qaybinta.

Codsiga fiilada qaybinta -1

Astaamaha:

Sifooyin farsamo iyo deegaan oo wanaagsan.

Astaamaha dab-damiska ayaa buuxiya shuruudaha heerarka khuseeya.

Astaamaha farsamada ee jacked waxay buuxiyaan shuruudaha heerarka khuseeya.

Jilicsan, dabacsan, si fudud loo dhigi karo oo loo kala qaybin karo, iyo gudbinta xogta awoodda weyn leh.

Buuxi shuruudaha kala duwan ee suuqa iyo macaamiisha.

Codsiga: loo isticmaalo fiilooyinka gudaha ee taageere-out fiilooyinka badan ee fiilooyinka pigtail/ balastar

+ Waxaa loo isticmaalaa dabada iyo fiilooyinka balastarada.

+ Waxaa loo isticmaalaa sidii khadadka isku xidhka qalabka, waxaana loo isticmaalaa isku xirka indhaha ee indhaha
qolalka isgaarsiinta iyo qaababka qaybinta indhaha.

+ Waxaa loo isticmaalaa fiilooyinka gudaha, gaar ahaan fiilo qaybinta.

Codsiga fiilada qaybinta -1

Baakad:

Baakadaha qaybinta fiilada -2
Xirmooyinka qaybinta fiilada-1

  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir