KCO-Fiver-MTP-MPO-QSFP-Banner-bogga-1

Fiilada Fiber-ka ee Dibadda ee Hal-Qaabka ah ee Dhexe ee Badhtamaha ah ee GYXTW

Sharaxaad Gaaban:

+ U isticmaal anteenada bannaanka.

+ Fiilada Fiber Optic-ga ee Dibadda ee Tareenka Dhexe,

+ Tirada faybarka: 2 faybar, 4 faybar, 6 faybar, 8 faybar, 12 faybar, 24 faybar.

+ Nooca faybarka: SM G652D, SM G657A1, SM G657A2, MM OM1, MM OM2, MM OM3, MM OM4, MM OM5

+ Fiilada korontada ku shaqeysa: PE, madow

+ Dhexroorka fiilada: 6.5mm, 7.0mm, 7.0mm

+ Daabacaadda fiilada iyo calaamadaynta: aqbal.


  • Qiimaha FOB:US $0.5 - 9,999 / Qayb
  • Tirada Dalabka Ugu Yar:100 Xabbo/Xabsi
  • Awoodda Bixinta:10000 Xabbo/Xabbadood bishiiba
  • Faahfaahinta Badeecada

    Calaamadaha Alaabta

    Astaamaha Farsamada Fiber Optic-ga GYXTW:

    Fiilada GYXTW Dhexroorka fiilada Miisaanka
    Tirada faybarka: 2 faybar ilaa 24 faybar 8.0mm+-0.5mm 70kg/km
    7.0mm+-0.3mm 50kg/km
    Heerkulka kala duwan -40°C+70°C
    Gacanka Laabista Ugu Yar (mm) Muddo dheer 10D
    Laabista Ugu YarGacanka (mm) Muddo gaaban 20D
    Xoogga Garaacista ee ugu yar ee la oggol yahay (N) Muddo dheer 1200
    Xoogga Garaacista ee ugu yar ee la oggol yahay (N) Muddo gaaban 1500
    Heerkulka Hawlgalka -40°C+70°C
    Heerkulka rakibidda -20°C+60°C
    Heerkulka kaydinta -40°C+70°C

    Astaanta Faybarka:

    Qaabka Faybarka Cutubka SM

    G652D

    SM

    G657A

    MM

    50/125

    MM

    62.5/125

    MM

    OM3-300

    MM

    OM4-550

    Xaalad nm 1310/1550 1310/625 850/1300 850/1300 850/1300 850/1300
    Hoos u dhac dB/km ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0 ≤3.5/2.2
    Kala Fidsanaan 1550nm Ps/(nm*km) ≤18 ≤18 ---- ----

    ----

    ----

      1625nm Ps/(nm*km) ≤22 ≤22 ---- ----

    ----

    ----

    Ballaca baaxadda 850nm MHZ.KM ----   ≥400 ≥160    
      1300nm MHZ.KM ----   ≥800 ≥500
    Mowjadda kala-fidinta eber nm ≥1302

    ≤1322

    ≥1302

    ≤1322

    ---- ---- ≥ 1295,

    ≤1320

    ≥ 1295,

    ≤1340

    Jiirada kala-fidinta eber nm ≤0.091 ≤0.090 ---- ---- ---- ----
    Fiber-ka Shakhsiga ah ee ugu Badan ee PMD ≤0.2 ≤0.2 ---- ---- ≤0.11  
    Qiimaha Isku xirka Naqshadeynta PMD Ps(nm2*km) ≤0.08 ≤0.1 ---- ---- ---- ----
    Mowjadaha dhererka faybarka λc nm ≥1180

    ≤1330

    ≥1180

    ≤1330

    ---- ---- ---- ----
    Xadhkaha fiilada

    hirarka λcc

    nm ≤1260 ≤1260 ---- ---- ---- ----
    MFD 1310nm um 9.2±0.4 9.0±0.4 ---- ---- ---- ----
      1550nm um 10.4±0.8 10.1±0.5 ---- ---- ---- ----
    Tiro ahaan

    Dalool (NA)

    ---- ---- 0.200± 0.015 0.275±

    0.015

    0.200±

    0.015

    0.200±

    0.015

    Tallaabo (celceliska labada jiho

    cabbir)

    dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Khaladaadka dhererka iyo barta faybarka dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Farqiga u dhexeeya dib-u-soo-kabashada

    isku-dhafka

    dB/km ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08 ≤0.08
    Midaysanaan yaraanshaha dB/km ≤0.01 ≤0.01  
    Dhexroorka xudunta um 9 9 50±1.0 62.5±2.5 50±1.0 50±1.0
    Dhexroorka dahaarka um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
    Dahaarka aan wareegsanayn % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
    Dhexroorka daahan um 242±7 242±7 242±7 242±7 242±7 242±7
    Dahaarka/chaffinch

    qalad si qotodheer loo sameeyay

    um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
    Dahaarka aan wareegsanayn % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
    Qaladka isku-xidhka xudunta/dahaadhka um ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5 ≤1.5
    Laablaab (gacan) um ≤4 ≤4 ---- ---- ---- ----

    Midabka faybarka:

    1 2 3 4 5 6
    Buluug Liin dhanaan Cagaaran Bunni Cawlan Caddaan
    7 8 9 10 11 12
    Casaan Madow Jaalle Fiyoolet Casaan Biyo
    Lambarka Faybar-Optic-File-Midabada

    Waa maxay fiilada GYXTW?

    Fiilada fiber optic-ga ee GYXTW, fiilooyinka 250μm, waxay ku jiraan tuubo dabacsan oo laga sameeyay balaastik modulus sare leh.

    Tuubooyinka waxaa ka buuxa isku-darka buuxinta biyaha u adkaysta.

    Tuubada waxaa lagu duubay lakab PSP ah oo dherer ahaan loo sameeyay.

    Inta u dhaxaysa PSP iyo qalabka biyaha ka ilaaliya tuubada dabacsan ayaa la mariyaa si fiilada looga dhigo mid isku xiran oo aan biyuhu geli karin.

    Laba fiilooyin bir ah oo is barbar socda ayaa la dhigayaa labada dhinac ee cajaladda birta ah.

    Fiilada waxaa lagu buuxiyaa jaakad polyethylene (PE), midab madow, si looga ilaaliyo fiilada UV.

    Dhismaha:

    Fiilada KCO GYXTW

    Astaamaha:

    Xubin siman oo bir ah, buuxiye ayaa ilaaliya cajalad bir ah oo fiilada tuubada ah oo la surfacay.

    Waxqabad farsamo iyo deegaan oo heer sare ah.

    Qaab-dhismeedka is haysta, miisaan fudud ayaa si habboon loogu rakibi karaa oo si fudud loogu shaqeyn karaa.

    Fiber kale ayaa la heli karaa ikhtiyaar: Hab keli ah (G652D, G657A, G657B) iyo Multimode (OM1, Om2, Om3, OM4, OM5)

    Tirada faybarka: 2fo ~ 12fo

    Ikhtiyaarka dhexroorka: 6.0mm, 7.0mm (shaqadii hore), 8.0mm

    Codsiga:

    + Waxaa loo qaatay qaybinta bannaanka.

    + Ku habboon habka hawo-mareenka, habka gelinta dhuumaha.

    + Isgaarsiinta shabakadda masaafada dheer iyo deegaanka.

    OM3 5025 GYXTW Optic5 Dibadda ah

    Baakad:

    Warshadda Fiber Optic ee KCO

  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir