Sharaxaad Gaaban:

KCO QSFP28 100G ZR4 waxaa loogu talagalay codsiyada isgaarsiinta indhaha ee 80km.

Module-kani wuxuu ka kooban yahay gudbiye indhaha ah oo 4-laad ah, qaataha indhaha ee 4-laad ah iyo baloogga maaraynta module-ka oo ay ku jiraan 2 silig oo is-dhexgal taxane ah.

Calaamadaha indhaha waxaa lagu dhejiyaa fiilada hal-qaab ah iyada oo loo marayo isku xirka LC-ga caadiga ah ee warshadaha.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Ku saabsan ModSeIL

+ ModSelL waa biin gelinta ah. Marka martigeliyaha uu hoos u hayo, module-ku wuxuu ka jawaabaa amarrada isgaarsiinta taxanaha ah ee 2-fiilo leh.

+ ModSelL wuxuu u oggolaanayaa isticmaalka modules badan oo ku yaal hal bas oo isku xiran oo 2-wire ah. Marka ModSelL uu yahay "Sare", moduleku kama jawaabi doono ama ma aqoonsan doono isgaarsiinta isku xiran ee 2-wire ah ee ka timaadda martida.

+ Qalooca gelinta calaamadda ModSelL waa inuu u janjeeraa xaaladda "Sare" ee module-ka.+ Si looga fogaado khilaafaadka, nidaamka martigeliyaha waa inaanu isku dayin isgaarsiinta is-dhexgalka 2-wire gudahood waqtiga ka-noqoshada ModSelL ka dib marka laga saaro modules kasta.

+ Sidoo kale, martigeliyaha waa inuu sugaa ugu yaraan muddada waqtiga xaqiijinta ModSelL ka hor inta uusan la xiriirin module-ka cusub ee la doortay.

+ Xilliyada sheegashada iyo ka-noqoshada ee cutubyada kala duwan ayaa is dul mari kara ilaa inta shuruudaha wakhtiga ee kor ku xusan la buuxiyo.

Astaamaha

+Waafaqsan 100GBASE-ZR4

+Heerarka khadka taageerada laga bilaabo 103.125 Gb/s ilaa 111.81 Gb/s OTU4

+LAN WDM EML laser iyo qaataha PIN oo leh SOA

+Ilaa 80km oo gaari kara G.652 SMF

+Isku-xirka korontada ee 38-biin ah oo kulul oo la xiri karo

+Waafaqsan QSFP28 MSA

+Qolka jiifka ee duplex LC

+U hoggaansan RoHS-10 iyo rasaas la'aan

+Koronto hal + 3.3V ah

+Isticmaalka awoodda ugu badan 6.5W

+Heerkulka hawlgalka kiiska: Ganacsi: 0 ~ +70oC/La dheereeyay: -10 ~ +80oC/Warshadaha: -40 ~ +85oC

Codsiyada

+Xiriirada Ethernet-ka 100GBASE-ZR4

+Isku xirka Infiniband QDR iyo DDR

+Shabakadda Isgaarsiinta

Qiimaynta Ugu Badan ee Dhabta ah

Waa in la ogaadaa in hawlgalka ka badan qiimeynta ugu badan ee shaqsiga ah uu sababi karo dhaawac joogto ah oo ku yimaada module-kan.

Halbeegga

Astaan

Ugu yaraan

Ugu badnaan

Cutubka

Qoraallo

Heerkulka Kaydinta

TS

-40

85

oC

Danab Bixinta Korontada

VCC

-0.3

4.0

V

Qoyaanka Qaraabada ah (aan biyuhu lahayn)

RH

15

85

%

Xadka Burburka

THd

6.5

dBm

Xaaladaha Hawlgalka ee lagu taliyay

Halbeegga

Astaan

Ugu yaraan

Caadi ah

Ugu badnaan

Cutubka

Qoraallo

Heerkulka Kiiska Hawlgalka

TOP

0

70

oC

ganacsi

-10

80

la dheereeyay

-40

85

Warshadaha

Danab Bixinta Korontada

VCC

3.135

3.3

3.465

V

Heerka Xogta, Layn kasta

25.78125

Gb/s

Kontoroolka Kontoroolka Kontoroolka Sare

2

Vcc

V

Kontoroolka Danabka gelinta oo hooseeya

0

0.8

V

Masaafada Isku xirka (SMF)

D

80

km

1

Qoraalo:

1. Iyada oo ku xidhan luminta dhabta ah ee faybarka/km (masaafada isku xidhka ee la cayimay waa luminta gelinta faybarka ee 0.35dB/km)

Cabbirrada

KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fiber Opt

Xuduudaha alaabta

Qaabka Qodobka

QSFP28

Heerka Xogta Ugu Badan

100 Gbps

Mowjadda hirarka

1294-1310nm

Mowjadda Dhexe

1295,1300,1304,1309nm

Masaafada ugu Badan ee Fiilada

80KM

Nooca isku xidhka

LC

Nooca fiilada faybarka

SMF

Magaca Iibiyaha

KCO

Nooca Gudbiyaha

EML

Nooca Qaadaha

SOA+PIN

Awoodda Gudbinta

2 ilaa +6.5 dBm

Dareenka ugu sarreeya ee qaataha

– 28 dBm

Awoodda xad-dhaafka ah

6.5 dBm

Saamiga Dabar-goynta

6 dB

DDM

La taageeray

Heerkulka Hawlgalka.

0°C ilaa 70°C


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir