Cufnaanta Sare 96fo MPO Fiber Optic Patch Panel oo leh 4 qaybood
Sharaxaad
+ Qaab-dhismeedka qaybinta indhaha ee lagu rakibay rack (ODF) KCO-MPO-1U-01 waa aaladda ka baxda fiilooyinka indhaha iyo qalabka isgaarsiinta indhaha, iyadoo leh shaqada isku-xidhka, joojinta, kaydinta iyo hagaajinta fiilooyinka indhaha.
+ Guddi gaar ah oo balastar ah waa sanduuq fiilooyin ah oo MPO ah oo cufnaan aad u sarreeya leh oo hore loo joojiyay, 19-inji, dhererkiisuna yahay 1U.
+ Waa naqshad gaar ah oo loogu talagalay xarunta xogta kaas oo guddi kasta oo balastar ah uu rakibi karo ilaa 96 xudunta LC.
+ Waxaa loo isticmaali karaa codsiyada fiilooyinka cufnaanta sare leh sida xarumaha kombiyuutarka, qolalka kombiyuutarka, iyo keydka xogta.
+ Daboolka sare ee laga saari karo hore iyo gadaal, hagaha laba-jibbaaran ee la soo bixin karo, garka hore ee la saari karo, sanduuqa module-ka fudud ee ABS iyo codsiyada kale ee farsamada ayaa sahlaya in loo isticmaalo muuqaallada cufnaanta badan ha ahaato fiilada ama fiilada.
+ Guddi-sameeyahan balastarku wuxuu leeyahay wadarta saxaaradaha lakabka E, mid walbana wuxuu leeyahay bir-hage aluminium ah oo madax-bannaan.
+ Afar sanduuq oo MPO ah ayaa lagu rakibay saxaarad kasta, sanduuq kasta oo module ahna waxaa lagu rakibay 12 adapter DLC ah iyo 24 xudunta.
Codsiga farsamada
| Xogta Farsamada | Xogta | |
| P/N | KCO-MPO-1U-01-96 | |
| Alaab | Cajalad bir ah | |
| Qaybta MPO | La heli karo | |
| Qalabka moduleka | Balaastig | |
| Dekedda module-ka | Dekedda LC Duplex: 12 | |
| Dekedda MPO: 2 | ||
| Habka rakibidda moduleka | Nooca Baakadaha leh | |
| Nooca faybarka | Habka Heesta (SM) 9/125 | MM (OM3, OM4, OM5) |
| Tirada faybarka | 8fo/ 12fo / 16fo / 24fo | |
| Lumitaanka gelinta | LC ≤ 0.5dB | LC ≤ 0.35dB |
| MPO ≤ 0.75dB | MPO ≤ 0.35dB | |
| Lumista soo celinta | LC ≥ 55dB | LC ≥ 25dB |
| MPO ≥ 55dB | MPO ≥ 25dB | |
| Deegaanka | Heerkulka Hawlgalka: -5°C ~ +40°C | |
| Heerkulka kaydinta: -25°C ~ +55°C | ||
| Qoyaan qaraabo ah | ≤95% (+40°C) | |
| Cadaadiska jawiga | 76-106kpa | |
| Waarta gelinta | ≥1000 jeer | |
Qaybta MPO
Macluumaadka dalbashada
| P/N | Lambarka module-ka. | Nooca Faybarka | Nooca Module-ka | Isku xiraha 1 | Isku xiraha 2 |
| KCO-MPO-1U-01 | 1 2 3 4 | SM OM3-150 OM3-300 OM4 OM5 | 12fo 12fo*2 24fo | MPO/APC MPO SM MPO OM3 MPO OM4 | LC/UPC LC/APC LC MM LC OM3 LC OM4 |
| KCO-MPO-2U-01 | 1 2 3 4 5 6 7 8 | SM OM3-150 OM3-300 OM4 OM5 | 12fo 12fo*2 24fo | MPO/APC MPO SM MPO OM3 MPO OM4 | LC/UPC LC/APC LC MM LC OM3 LC OM4 |