FTTH 3 Dekedood Shaandhaynta Mowjadaha Qaybta Multiplexer 1310 1490 1550nm Fiber Optic FWDM SC/UPC SC/APC
Tilmaamaha
| Nooca | FWDM | |
| Mowjadda Hawlgalka T: hirarka gudbinta R: dhererka milicsiga 1310±50,1490±10, 1550±10 1610±10, 1625±25, 1650±20 | nm | T1550 R1310/1490 |
| T1490 R1310/1550 | ||
| T1310 R1490/1550 | ||
| T1550/1610 R1310/1490 | ||
| T1550/1625 R1310/1490 | ||
| T1625 R1310/1490/1550 | ||
| T1650 R1310/1490/1550 | ||
| Lumista gelinta gudbinta | dB | ≤0.80 |
| Lumista gelinta milicsiga | dB | ≤0.60 |
| Go'doominta kanaalka gudbinta | dB | ≥30 |
| Go'doominta kanaalka milicsiga | dB | ≥17 |
| PDL | dB | ≤0.1 |
| Xasiloonida kuleylka ee hirarka | nm/℃ | ≤0.003 |
| Xasiloonida kulaylka ee luminta gelinta | dB/℃ | ≤0.005 |
| Tilmaamaha | dB | ≥55 |
| Lumista soo celinta | dB | ≥45 |
| Heerkulka hawlgalka | ℃ | -20~+70 |
| Heerkulka kaydinta | ℃ | -40~+85 |
Fiiro gaar ah: 1. Habayn ayaa la heli karaa.
2. Lagu qeexay iyada oo aan lahayn isku xire, oo ku dar khasaare dheeraad ah oo ah 0.2dB isku xire kasta.
Sharaxaadda Badeecada
•Qaybta Multiplexer-ka ee Shaandhada Fiber Optic-ga (FWDM) waxay ku salaysan tahay tignoolajiyada shaandhada khafiifka ah ee deegaanka deggan.
•Qalabkani wuxuu isku daraa ama kala saaraa iftiinka hirarka kala duwan ee kala duwan iyadoo la adeegsanayo hirar ballaaran.
•Waxay bixiyaan lumis gelinta oo aad u yar, ku tiirsanaan hoose oo kala-goyn ah, go'doomin sare iyo xasillooni deegaan oo aad u fiican. Awood maareyn awood sare leh ayaa lagu gaari karaa iyada oo loo marayo habayn gaar ah oo loogu talagalay dahaarka doofaarka iyo dahaarka AR oo tayo sare leh.
•Qaybahan waxaa si ballaaran loogu isticmaalay EDFAs, amplifiers-ka Raman, shabakadaha WDM iyo qalabka fiber optical-ka.
•Kala-soocidda Wareegga Shaandhaynta (FWDM), FWDM T1550 R1310&1490 waxay gaari kartaa 1550/1310 & 1490 laba kanaal oo isku-dhufashada calaamadaha indhaha iyo kala-soocidda.
•Samaynta hal awood gudbinta fiber optic ah oo isku dhufasho ah, si ballaaran loogu isticmaalo casriyeynta shabakadda fiber optic iyo CATV iwm.
•Qalabku wuxuu leeyahay lumis hoose oo gelinta ah, waddo indhaha oo aan lahayn epoxy, saamiga dabar-goynta sare, isku hallayn sare iyo xasillooni sare.
•Habka baakadka: Tuubo bir ah, sanduuq qaabaysan oo madow oo ABS ah.
•Fiilo indhaha ah oo qaawan, 0.9 mm, 2.0 mm, iyo 3.0 mm Fiilo gelinta/soo-saarka ah.
•Fiilo indhaha ah oo qaawan, 0.9 mm, 2.0 mm, iyo 3.0 mm Fiilo gelinta/soo-saarka ah.
Codsiyada
- HFC (shabakadda fiber-ka iyo coaxial-ka ee CATV, CCTV)
- Dhammaan codsiyada FTTH.
- Nidaamka shabakadda fiber optic-ga ee dadban.
Astaamaha
•Farsamooyinka sameynta FBT ee la xaqiijiyay
•Waxqabadka Broadband
•Deegaan ahaan deggan
•Kala-fogaanshaha aan dareen lahayn
•Xirmo yar ama adag
•Xidhiidhiyayaasha caadiga ah iyo fiilooyinka fiilada ayaa diyaar ah.
•Waxaa soo saaray tignoolajiyada isku dhafan.
•Lumis Gelin Hoose (IL)
•Go'doomin sare-
•Lumis Ku-tiirsan Kala-goysyada Hoose (PDL)
•Shaandhada WDM ee 1x2 oo leh naqshad is haysta
•Kala duwanaansho ballaaran oo hirarka hawlgalka ah
•Kalsooni sare iyo xasillooni sare
Cabbirka tuubada birta ah ee FWDM:
Habka baakadaynta FFDM: