Nooca Hagaajinta 19 Inch Cufnaanta Sare 96 Cores MPO MTP Optical Fiber Patch Panel
Sharaxaad
+ Guddiyada balastarrada fiber optic-ga ee nooca go'an waa kuwo bir ah oo ku dheggan rack (heerka 19-inji) oo bixiya cimri dherer sare, amni, iyo maaraynta fiber-ka oo habaysan.
+ Waxaa loogu talagalay deegaannada leh isbeddello soo noqnoqosho yar, waxay si ammaan ah u hayaan adapters-ka (LC, SC, ST, FC), saxaarado isku-dhafan oo loogu talagalay isku-xidhka isku-dhafka, iyo qaybaha maaraynta fiilooyinka ee qaab-dhismeedka 1U, 2U, ama ka sareeya.
+ Guddi-sameeyahan balastar-ka fiber optic-ga ah wuxuu ku jiraa rack-mount (19" caadi ah), waxay hayaan module-ka fiber optic-ga ee ku raran fiilada balastar-ka ee MPO ilaa LC.
+ Guddiga balastar-ka ee ku rakiban raafka KCO-MPO-1U-96-FX waa 96 xudunta sanduuqa joojinta fiber optic-ga ee qaab-dhismeedka qaybinta fiber optic-ga caadiga ah ee 19''.
+ Waa aaladda ka dhammata fiilooyinka indhaha iyo qalabka isgaarsiinta indhaha, iyadoo leh shaqada isku xidhka, joojinta, kaydinta iyo hagaajinta fiilooyinka indhaha.
+ Guddi gaar ah oo balastar ah waa sanduuq fiilooyin cufnaan aad u sarreeya oo MTP MPO ah oo hore loo joojiyay, dhererkiisuna yahay 19-inji, 1U.
+ Waa naqshad gaar ah oo loogu talagalay xarunta xogta kaas oo guddi kasta oo balastar ah uu rakibi karo ilaa 96 xudunta dekedda LC.
+ Astaamaha ugu muhiimsan iyo codsiga:
Fiilooyinka Qaabaysan: Waxaa loo isticmaalaa xarun dhexe qolalka isgaarsiinta, xafiisyada dhexe, iyo xarumaha xogta si loo maareeyo fiilooyinka cufnaanta sare leh.
Joojinta: Waxay taageertaa isku xirayaasha joojinta goobta iyo isku-xidhka, iyadoo leh saxaarado gudaha ah oo loogu talagalay isku-xidhka iyo maaraynta fiilada.
Ilaalinta & Amniga: Waxay bixisaa guri bir ah oo waara oo loogu talagalay isku xirka fiilooyinka jilicsan, iyadoo ka ilaalinaysa xiisadda, foorarsiga, ama dhaawaca fiilooyinka.
Kala Duwanaanshaha: Waxay taageertaa noocyada kala duwan ee adapter-ka (SC, LC, ST, FC) iyo polarities-ka isku xirka (fudud ama duplex), iyagoo bixinaya naqshad 19-inji ah oo lagu rakibay rack-ka caadiga ah.
Casriyeynta Nidaamka: Waxay sahlaysaa dayactirka shabakadda oo fudud, xallinta dhibaatooyinka, iyo dhaqaajinta, ku darista, iyo isbeddellada (MACs).
+ Fiilada MPO Patch Nooca B:
Xogta farsamada
+ Cabbirka: 485*300*44.5 (mm)
+ Awoodda: 96 xudunta
+ Qalabka: Cajalad bir ah (ikhtiyaar: cajalad aluminium ah 1.4mm ama ka badan)
+ Dhumuc: Caadiga ah 1.0mm (Ikhtiyaar: 0.8mm, 1.2mm, 1.4mm)
+ Heerkulka hawlgalka: -5°C ~ +40°C;
+ Heerkulka kaydinta: -25°C ~ +55°C
+ Qoyaan qaraabo ah: ≤95% (+40°C)
+Cadaadiska jawiga: 76-106kpa
+ Lumitaanka gelinta:
Nooca caadiga ah: 0.65dB
Nooca Sare: 0.35dB
+ RL:
Hab keli ah: 65dB
Qaab-badan: 35dB
+ Adkeysiga gelinta: ≥1000 jeer
Guddiga Balastareynta MPO 1U
Macluumaadka dalbashada
| P/N | Lambarka module-ka. | Nooca Faybarka | Nooca Module-ka | Isku xiraha 1 | Isku xiraha 2 |
| KCO-MPO-1U-96 | 1 2 3 4 | SM OM3-150 OM3-300 OM4 OM5 | 8fo*3 12fo*2 24fo*1 | MPO-8 MPO-12 MPO-24 | LC |
| KCO-MPO-2U-192 | 1 2 3 4 5 6 7 8 | SM OM3-150 OM3-300 OM4 OM5 | 8fo*3 12fo*2 24fo*1 | MPO-8 MPO-12 MPO-24 | LC |