KCO-Fiver-MTP-MPO-QSFP-Banner-bogga-1

1.25Gb/s 1310nm Gudbiyaha SFP ee Hal-qaab ah

Sharaxaad Gaaban:

Qalabka gudbiyaha ee Small Form Factor (SFP) waxay la jaan qaadayaan Heshiiska Small Form Factor ee Multi-Sourcing (MSA). Qalabka gudbiyaha wuxuu ka kooban yahay afar qaybood: darawalka LD, amplifier-ka xaddidan, FP laser-ka iyo PIN photo-detector-ka. Xogta module-ku waxay ku xiran tahay ilaa 20km fiber-ka hal-qaabka ah ee 9/125um.

Wax soo saarka indhaha waxaa lagu joojin karaa iyadoo la adeegsanayo TTL logic heer sare ah oo Tx Disable ah. Tx Fault waxaa la bixiyaa si loo muujiyo burburka laysarka. Lumitaanka wax soo saarka calaamadda (LOS) ayaa la bixiyaa si loo muujiyo lumitaanka calaamadda indhaha ee qaataha ama xaaladda xiriirka ee lammaanaha.


Faahfaahinta Badeecada

Calaamadaha Alaabta

Tilmaamaha Badeecada

+ Xiriirinta xogta ilaa 1.25Gb/s
+ Gudbiyaha laser-ka FP iyo sawir-qaade PIN ah
+ Ilaa 20km oo ku socota 9/125µm SMF
+ Raad-raaca SFP ee kulul ee la xiri karo
+ Nooca Duplex LC/UPC interface indhaha ah oo la xiri karo
+ Kala firdhis awood yar
+ Qalab bir ah, oo loogu talagalay EMI hoose
+ U hoggaansan RoHS iyo hoggaan la'aan
+ Koronto keli ah + 3.3V
+ Waafaqsan SFF-8472
+ Heerkulka hawlgalka kiiska
Ganacsi: 0°C ilaa +70°C
La dheereeyay: -10°C ilaa +80°C

Codsiyada

+ U gudub Is-dhexgalka Beddelka

+ Gigabit Ethernet

+ Codsiyada Backplane-ka ee la beddelay

+ Isku-xirka router-ka/server-ka

+ Xiriiro kale oo indhaha ah

Macluumaadka dalbashada

Lambarka Qaybta Badeecada

Heerka Xogta

(Mbps)

Warbaahinta

Mowjadda hirarka

(nm)

Gudbinta

Masaafada (km)

Kala Duwan Heerkulka (Kiiska) (℃)

KCO-SFP-1.25-SM-20C

1250

Fiber qaab keli ah

1310

20

0~70

ganacsi

KCO-SFP-1.25-SM-20E

1250

Fiber qaab keli ah

1310

20

-10~80

la dheereeyay

KCO-SFP-1.25-SM-20A

1250

Fiber qaab keli ah

1310

20

-40~85

warshadaha

Sharaxaadaha Biinanka

Biin

Astaan

Magaca/Sharaxaadda

OGAYSIIS

1

VEET

Dhulka Gudbiyaha (Caadiga Dhulka Qaadaha)

1

2

TFAULT

Ciladda Gudbiyaha.

3

TDIS

Gudbiye Dami. Wax soo saarka laysarka ayaa la damiyay marka sare ama furan yahay.

2

4

MOD_DEF(2)

Qeexitaanka Module-ka 2. Khadadka xogta ee Aqoonsiga Taxanaha.

3

5

MOD_DEF(1)

Qeexitaanka Module-ka 1. Khadadka saacadda ee Aqoonsiga Taxanaha.

3

6

MOD_DEF(0)

Qeexitaanka Module 0. Ku salaysan moduleka dhexdiisa.

3

7

Dooro Qiimee

Looma baahna xidhiidh

4

8

LOS

Lumitaanka calaamadda. Macnaha 0 wuxuu tilmaamayaa hawlgal caadi ah.

5

9

VEER

Goobta Qaadaha (Caadiga Dhulka Gudbiyaha)

1

10

VEER

Goobta Qaadaha (Caadiga Dhulka Gudbiyaha)

1

11

VEER

Goobta Qaadaha (Caadiga Dhulka Gudbiyaha)

1

12

RD-

Qalabka qaataha ayaa la rogay xogta. AC waa la isku xidhay

13

RD+

DATA-ka qaataha oo aan la rogin. AC-ga waa la isku xidhay

14

VEER

Goobta Qaadaha (Caadiga Dhulka Gudbiyaha)

1

15

VCCR

Qalabka Korontada ee Qaadaha

16

VCCT

Qalabka Korontada Gudbiyaha

17

VEET

Dhulka Gudbiyaha (Caadiga Dhulka Qaadaha)

1

18

TD+

XOGTA Gudbiyaha ee aan la rogin ee ku jirta AC-ga oo la isku xidhay.

19

TD-

XOGTA LA ROGAY EE Gudbiyaha oo la rogay. AC oo la isku xidhay.

20

VEET

Dhulka Gudbiyaha (Caadiga Dhulka Qaadaha)

1

Qoraalo:
1. Dhulka wareegga waxaa gudaha looga go'doomiyay dhulka chassis-ka.
2. Wax soo saarka laysarka ayaa la damiyay TDIS >2.0V ama furan, waxaana la shiday TDIS <0.8V.
3. Waa in la jiidaa iyadoo la isticmaalayo 4.7k - 10kohms oo ku yaal looxa martida loo yahay ilaa danab u dhexeeya 2.0V iyo 3.6V. MOD_DEF (0) wuxuu jiidayaa xariiq hoose si uu u muujiyo in moduleku ku xiran yahay.
4. Kani waa gelin ikhtiyaari ah oo loo isticmaalo in lagu xakameeyo xawaaraha qaataha si loogu waafajiyo heerarka xogta badan (waxay u badan tahay Fiber Channel 1x iyo 2x Heerarka). Haddii la hirgeliyo, gelintu gudaha ayay hoos ugu dhici doontaa iyadoo la adeegsanayo iska caabin > 30kΩ. Xaaladaha gelintu waa:
- Hoose (0 – 0.8V): Ballaca oo La Yareeyay
- (>0.8, < 2.0V): Aan la qeexin
- Sare (2.0 – 3.465V): Ballac Buuxa
- Furan: Balan-ballaadh la dhimay
5.LOS waa wax soo saarka ururiyaha furan waa in la jiidaa iyadoo 4.7k - 10kohms lagu rakibayo guddiga martida loo yahay ilaa danab u dhexeeya 2.0V iyo 3.6V. Logic 0 waxay muujinaysaa hawlgal caadi ah; logic 1 waxay muujinaysaa luminta calaamadda.

Jaantuska 2. Biinka ka soo saar Baloogga Xidhiidhiyaha ee ku yaal Looxa Martigelinta

Tilmaamaha Farsamada (Cutubka: mm)