Bogga calanka

KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fiber Optic Transceiver

Sharaxaad Gaaban:

KCO QSFP28 100G ZR4 waxaa loogu talagalay 80km codsiyada isgaarsiinta indhaha.

Qaybtani waxa ay ka kooban tahay gudbiyaha indhaha ee 4-haad ah, 4-haad soo dhawe indhaha ah iyo block maaraynta moduleka oo ay ku jiraan 2 silig oo is dhexgal ah.

Calaamadaha indhaha ayaa lagu dhuftey fibre-hal-hal-hal ah iyada oo loo marayo isku-xiraha heerka LC ee warshadaha.


Faahfaahinta Alaabta

Tags Product

Ku saabsan ModSeIL

+ ModSelL waa biin gelinta. Marka uu hooseeyo martigeliyaha, cutubku waxa uu ka jawaabayaa amarada isgaarsiineed ee 2-fire ah.

+ ModSelL wuxuu u oggolaanayaa isticmaalka qaybo badan oo bas ah oo 2-fire ah. Marka ModSelL uu yahay "Sare", moduleka waa inuusan ka jawaabin ama aqoonsan wax xiriir ah oo 2-fire ah oo ka yimaada martida loo yahay.

+ ModSelL soo gelista signalada waa in loo eexdo "High" gobolka moduleka.+ Si looga fogaado isku dhacyada, nidaamka martigeliyaha waa inuusan isku dayin isgaarsiin 2-fire ah gudaha ModSelL dib-u-xaqiijinta waqtiga ka dib qayb kasta oo aan la dooran

+ Sidoo kale, martida loo yahay waa inay sugaan ugu yaraan muddada ModSelL caddaynta ka hor inta aan lala xidhiidhin qaybta cusub ee la doortay.

+ Muddada caddaynta iyo caddaynta ee cutubyada kala duwan ayaa laga yaabaa inay is dulmaanaan ilaa inta shuruudaha kor ku xusan la buuxiyo.

Astaamaha

+U hoggaansan 100GBASE-ZR4

+Heerarka khadka taageerada laga bilaabo 103.125 Gb/s ilaa 111.81 Gb/s OTU4

+LAN WDM EML laser iyo PIN qaataha leh SOA

+Ilaa 80km waxay gaadhaysaa G.652 SMF

+Hot pluggable 38 pin korantada interface

+QSFP28 MSA u hoggaansan

+Qalabka indhaha ee Duplex LC

+RoHS-10 u hoggaansan oo aan lahayn rasaasta

+Hal + 3.3V koronto

+Isticmaalka tamarta ugu badan 6.5W

+Heerkulka shaqada kiiska: Ganacsi: 0 ~ +70oC/kordhinta: -10 ~ +80oC/ Warshadaha: -40 ~ +85oC

Codsiyada

+100GBASE-ZR4 Ethernet Links

+Infiniband QDR iyo DDR isku xira

+Isku xirka isgaarsiinta

Qiimaynta ugu Sarreysa

Waa in la ogaadaa in qalliinka ka badan qiimaynta ugu sarraysa ee shakhsi ahaaneed ay keeni karto dhaawac joogto ah oo soo gaara cutubkan.

Halbeegga

Astaanta

Min

Max

Unug

Xusuusin

Heerkulka Kaydinta

TS

-40

85

oC

Korontada Supply

VCC

-0.3

4.0

V

Qoyaanka Qaraabada (aan uumi lahayn)

RH

15

85

%

Xadka Burburka

THd

6.5

dBm

Shuruudaha Hawleed ee lagu taliyay

Halbeegga

Astaanta

Min

Caadiyan

Max

Unug

Xusuusin

Heerkulka Kiis Shaqaynta

TOP

0

70

oC

ganacsi

-10

80

la dheereeyey

-40

85

Warshadaha

Korontada Supply

VCC

3.135

3.3

3.465

V

Heerka Xogta, Haad kasta

25.78125

Gb/s

Xakamaynta Input Voltage High

2

Vcc

V

Xakamaynta Gelitaanka Voltage Hoose

0

0.8

V

Fogaanta isku xidhka (SMF)

D

80

km

1

Xusuusin:

1. Waxay kuxirantahay khasaaraha dhabta ah ee fiber-ka/km ( masaafada iskuxiran ee la cayimay waa luminta fiber galinta 0.35dB/km)

Cabirka

KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fiber Opt

Xuduudaha alaabta

Qodobka Foomka

QSFP28

Heerka ugu badan ee Xogta

100 Gbps

Mawjada dhererka

1294-1310nm

Hirarka dhexda

1295,1300,1304,1309nm

Masaafada ugu badan ee Cable

80KM

Nooca xiriiriyaha

LC

Nooca Fiber Fiber

SMF

Magaca Iibiyaha

KCO

Nooca Gudbiyaha

EML

Nooca qaataha

SOA+PIN

Gudbinta Awoodda

2 ilaa +6.5 dBm

Dareenka qaataha ugu badan

-28 dBm

Awood-kordhinta

6.5 dBm

Saamiga Dabar goynta

6 dB

DDM

Taageeray

Heerkulka Shaqada

0°C ilaa 70°C


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir