KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fiber Optic Transceiver
Ku saabsan ModSeIL
+ ModSelL waa biin gelinta. Marka uu hooseeyo martigeliyaha, cutubku waxa uu ka jawaabayaa amarada isgaarsiineed ee 2-fire ah.
+ ModSelL wuxuu u oggolaanayaa isticmaalka qaybo badan oo bas ah oo 2-fire ah. Marka ModSelL uu yahay "Sare", moduleka waa inuusan ka jawaabin ama aqoonsan wax xiriir ah oo 2-fire ah oo ka yimaada martida loo yahay.
+ ModSelL soo gelista signalada waa in loo eexdo "High" gobolka moduleka.+ Si looga fogaado isku dhacyada, nidaamka martigeliyaha waa inuusan isku dayin isgaarsiin 2-fire ah gudaha ModSelL dib-u-xaqiijinta waqtiga ka dib qayb kasta oo aan la dooran
+ Sidoo kale, martida loo yahay waa inay sugaan ugu yaraan muddada ModSelL caddaynta ka hor inta aan lala xidhiidhin qaybta cusub ee la doortay.
+ Muddada caddaynta iyo caddaynta ee cutubyada kala duwan ayaa laga yaabaa inay is dulmaanaan ilaa inta shuruudaha kor ku xusan la buuxiyo.
Astaamaha
+U hoggaansan 100GBASE-ZR4
+Heerarka khadka taageerada laga bilaabo 103.125 Gb/s ilaa 111.81 Gb/s OTU4
+LAN WDM EML laser iyo PIN qaataha leh SOA
+Ilaa 80km waxay gaadhaysaa G.652 SMF
+Hot pluggable 38 pin korantada interface
+QSFP28 MSA u hoggaansan
+Qalabka indhaha ee Duplex LC
+RoHS-10 u hoggaansan oo aan lahayn rasaasta
+Hal + 3.3V koronto
+Isticmaalka tamarta ugu badan 6.5W
+Heerkulka shaqada kiiska: Ganacsi: 0 ~ +70oC/kordhinta: -10 ~ +80oC/ Warshadaha: -40 ~ +85oC
Codsiyada
+100GBASE-ZR4 Ethernet Links
+Infiniband QDR iyo DDR isku xira
+Isku xirka isgaarsiinta
Qiimaynta ugu Sarreysa
Waa in la ogaadaa in qalliinka ka badan qiimaynta ugu sarraysa ee shakhsi ahaaneed ay keeni karto dhaawac joogto ah oo soo gaara cutubkan.
| Halbeegga | Astaanta | Min | Max | Unug | Xusuusin |
| Heerkulka Kaydinta | TS | -40 | 85 | oC |
|
| Korontada Supply | VCC | -0.3 | 4.0 | V |
|
| Qoyaanka Qaraabada (aan uumi lahayn) | RH | 15 | 85 | % |
|
| Xadka Burburka | THd | 6.5 |
| dBm |
Shuruudaha Hawleed ee lagu taliyay
| Halbeegga | Astaanta | Min | Caadiyan | Max | Unug | Xusuusin |
| Heerkulka Kiis Shaqaynta | TOP | 0 |
| 70 | oC | ganacsi |
| -10 |
| 80 | la dheereeyey | |||
| -40 |
| 85 | Warshadaha | |||
| Korontada Supply | VCC | 3.135 | 3.3 | 3.465 | V |
|
| Heerka Xogta, Haad kasta |
|
| 25.78125 |
| Gb/s |
|
| Xakamaynta Input Voltage High |
| 2 |
| Vcc | V |
|
| Xakamaynta Gelitaanka Voltage Hoose |
| 0 |
| 0.8 | V |
|
| Fogaanta isku xidhka (SMF) | D |
|
| 80 | km | 1 |
Xusuusin:
1. Waxay kuxirantahay khasaaraha dhabta ah ee fiber-ka/km ( masaafada iskuxiran ee la cayimay waa luminta fiber galinta 0.35dB/km)
Cabirka
Xuduudaha alaabta
| Qodobka Foomka | QSFP28 | Heerka ugu badan ee Xogta | 100 Gbps |
| Mawjada dhererka | 1294-1310nm | Hirarka dhexda | 1295,1300,1304,1309nm |
| Masaafada ugu badan ee Cable | 80KM | Nooca xiriiriyaha | LC |
| Nooca Fiber Fiber | SMF | Magaca Iibiyaha | KCO |
| Nooca Gudbiyaha | EML | Nooca qaataha | SOA+PIN |
| Gudbinta Awoodda | 2 ilaa +6.5 dBm | Dareenka qaataha ugu badan | -28 dBm |
| Awood-kordhinta | 6.5 dBm | Saamiga Dabar goynta | 6 dB |
| DDM | Taageeray | Heerkulka Shaqada | 0°C ilaa 70°C |