Bogga calanka

SFP+ -10G-LR

Sharaxaad Gaaban:

• 10Gb/s SFP+ Transceiver

• Kulul ku xidhan, Duplex LC, +3.3V, 1310nm DFB/PIN, Hal qaab, 10km


Faahfaahinta Alaabta

Tags Product

SFP+ -10G-LR Sharaxaada Alaabta:

SFP + -10G-LR waa module transceiver optical 10Gb/s oo loogu talagalay codsiyada isgaadhsiinta indhaha ee taxan ee 10Gb/s, isaga oo isu beddelaya 10Gb/s xog koronto oo taxane ah oo leh calaamadda indhaha ee 10Gb/s. Waxay u hoggaansamaan SFF-8431, SFF-8432 iyo IEEE 802.3ae 10GBASE-LR. Waxay ku bixisaa hawlaha ogaanshaha dhijitaalka ah iyada oo loo marayo isku xirka 2-fire interface sida lagu qeexay SFF-8472. Waxay ka kooban tahay fiilo kulul, casriyeyn fudud iyo qiiq yar oo EMI ah. Gudbiyaha 1310nm DFB ee waxqabadka sare leh iyo soo-dhoweeyaha PIN-dareenka sare wuxuu bixiyaa waxqabadka sare ee codsiyada Ethernet ilaa isku xirka dhererka 10km ee fiber-ka hal qaab.

Tilmaamaha SFP+ 10G:

Waxay taageertaa 9.95 ilaa 11.3Gb/s

Kulul-Pluggable

Xidhiidhiyaha LC Duplex

1310nm gudbiyaha DFB, PIN sawir qaade

SMF waxay isku xidhaa ilaa 10km

2-silig interface ee tilmaamaha maamulka waafaqsan
oo leh SFF 8472 interface la socodka ogaanshaha dhijitaalka ah

Korontada:+3.3V

Isticmaalka tamarta <1.5W

Heerkulka Ganacsiga: 0 ~ 70°C

Heerkulka Wershadaha: -40~ +85°C

RoHS waafaqsan

Codsiyada SFP+ 10G:

10GBASE-LR/LW Ethernet at 10.3125Gbps

SONET OC-192 / SDH

CPRI iyo OBSAI

10G Fiber Channel

Macluumaadka Dalbashada:

Lambarka Qaybta

Heerka Xogta

Fogaanta

Mawjada dhererka

Laser

Fiber

DDM

Xiriiriyaha

Heerkulka

SFP+ -10G-LR

10Gb/s

10km

1310nm

DFB/PIN

SM

Haa

DuplexLC

0 ~ 70°C

SFP+ -10G-LR-I

10Gb/s

10km

1310nm

DFB/PIN

SM

Haa

DuplexLC

-40~ +85°C

Qiimaynta ugu Sarreysa

Halbeegga

Astaanta

Min.

Caadiyan

Max.

Unug

Heerkulka Kaydinta

TS

-40

 

+85

°C

Heerkulka Hawlgelinta Kiis SFP+ -10G-LR

TA

0

 

70

°C

SFP+ -10G-LR-I

-40

 

+85

°C

Korontada Supply ee ugu badan

Vcc

-0.5

 

4

V

Qoyaanka Qaraabada

RH

0

 

85

%

Tilmaamaha Korontada (TOP = 0 ilaa 70 °C, VCC = 3.135 ilaa 3.465 Volts)

Halbeegga

Astaanta

Min.

Caadiyan

Max.

Unug

Ogow

Supply Voltage

Vcc

3.135

 

3.465

V

 

Bixinta Hadda

Icc

 

 

430

mA

 

Isticmaalka Korontada

P

 

 

1.5

W

 

Qaybta gudbiyaha:
Gelida carqaladaynta kala duwanaanta

Rin

 

100

 

Ω

1

Tx Gelida Dulqaadka Korantada ee Kaliya ee Dhamaaday (Ref VeeT)

V

-0.3

 

4

V

 

Lulida gelinta kala duwan

Vin, pp

180

 

700

mV

2

Gudbi Disable Voltage

VD

2

 

Vcc

V

3

Gudbi Awood Korantada

VEN

Vee

 

Vee+0.8

V

 

Qaybta qaataha:
Dulqaadka Korantada ee Soo-baxa Keliya

V

-0.3

 

4

V

 

Wax soo saarka Rx kala duwanaansho Voltage

Vo

300

 

850

mV

 

Kor u kaca iyo wakhtiga dayrta ee Rx

Tr/Tf

30

 

 

ps

4

Khaladka LOS

VKhaladka LOS

2

 

VccHOSTEYGA

V

5

LOS Caadi

VLOS caadiga ah

Vee

 

Vee+0.8

V

5

Xusuusin:1. Si toos ah ugu xidhan biinanka gelinta xogta TX. Isku-xidhka AC ee biinanka ilaa darawalka laser IC.
2. Per SFF-8431 Rev 3.0.
3. Gelida 100 ohms joojinta kala duwanaanshaha.
4. 20% -80%.
5. LOS waa wax soo saarka ururiyaha furan. Waa in lagu soo qaadaa 4.7k – 10kΩ oo saaran guddiga martida loo yahay. Hawlgalka caadiga ah waa macquul 0; luminta calaamaduhu waa macquul

Qiyaasaha indhaha (TOP = 0 ilaa 70°C, VCC = 3.135 ilaa 3.465 Volts)

Halbeegga

Astaanta

Min.

Caadiyan

Max.

Unug

Ogow

Qaybta gudbiyaha:
Hirarka dhexda

t

1290

1310

1330

nm

 

ballac muuqaal ah

λ

 

 

1

nm

 

Celceliska Awoodda Aragga

Pavg

-6

 

0

dBm

1

Awoodda indhaha OMA

Poma

-5.2

 

 

dBm

 

Laser Off Power

Poff

 

 

-30

dBm

 

Saamiga Dabar goynta

ER

3.5

 

 

dB

 

Ciqaabta Faafinta Gudbinta

TDP

 

 

3.2

dB

2

Qaylada xoojinta Qaraabada

Rin

 

 

-128

dB/Hz

3

Dulqaadashada Luminta Soo-noqoshada indhaha

 

20

 

 

dB

 

Qaybta qaataha:
Hirarka dhexda

λr

1260

 

1355

nm

 

Dareenka qaataha

Sen

 

 

-14.5

dBm

4

Dareenka Cadaadiska ah (OMA)

SenST

 

 

-10.3

dBm

4

Los Assert

LOSA

-25

 

-

dBm

 

Los Macmacaanka

LOSD

 

 

-15

dBm

 

Los Hysteresis

LOSH

0.5

 

 

dB

 

Culayska xad dhaafka ah

Sat

0

 

 

dBm

5

Milicsiga Qaataha

Rrx

 

 

-12

dB

 

Xusuusin:1. Celcelis ahaan tirooyinka korantadu waa wargelin kaliya, marka loo eego IEEE802.3ae.
2. Tirada TWDP waxay u baahan tahay guddiga martida loo yahay inuu noqdo SFF-8431 waafaqsan. TWDP waxaa lagu xisaabiyaa iyadoo la isticmaalayo koodka Matlab ee lagu bixiyay faqradda 68.6.6.2 ee IEEE802.3ae.
3. 12dB milicsiga.
4. Xaaladaha imtixaanada qaataha culayska leh ee IEEE802.3ae. Tijaabada CSRS waxay u baahan tahay guddiga martida loo yahay inuu noqdo mid waafaqsan SFF-8431.
5. Culayska xad dhaafka ah ee qaataha ee lagu cayimay OMA oo hoos imanaya xaalada walaaca ugu xun ee dhamaystiran.

Astaamaha wakhtiga

Halbeegga

Astaanta

Min.

Caadiyan

Max.

Unug

TX_Dami wakhtiga caddaynta

t_off

 

 

10

us

TX_Dami wakhtiga diidmada

t_on

 

 

1

ms

Wakhtiga la bilaabayo ku darista dib u dajinta TX_FAULT

t_int

 

 

300

ms

TX_FAULT laga bilaabo Cilad ilaa Sheegasho

t_cillad

 

 

100

us

TX_Dami wakhtiga dib u dajinta

t_dib u dejin

10

 

 

us

Waayida Qaadaha Wakhtiga Sheegista Calaamadaha

TA,RX_LOS

 

 

100

us

Waayida Qaadaha Wakhtiga Macmacaanka Calaamadaha

Td,RX_LOS

 

 

100

us

Qiyaasta-Dooro Waqtiga Beddelka

t_qiimaha

 

 

10

us

Saacadda Aqoonsiga Taxanaha ah

t_serial-saacad

 

 

100

kHz

Qoondaynta Pin

Jaantuska Isku-xidhaha Guddida Martigelinta Tirooyinka Pin iyo Magaca

badeecada3

Qeexitaannada Shaqada Pin

PIN

Magaca

Shaqada

Xusuusin

1

VeeT Dhulka gudbiyaha module

1

2

Qaladka Tx Ciladda Gudbiyaha Module

2

3

Tx Dami Dareemi gudbiyaha; Wuxuu damiyaa wax soo saarka laysarka gudbiyaha

3

4

SDL 2 gelinta xogta interface interface serial (SDA)

 

5

SCL 2 gelinta saacad is dhexgalka siligga ah (SCL)

 

6

MOD-ABS Module Maqan yahay, ku xidh VeeR ama VeeT ee moduleka

2

7

RS0 Qiimee dooro0, si ikhtiyaari ah u xakamee SFP+ qaataha. Markay sareeyso, heerka gelida xogta>4.5Gb/s; marka ay hooseyso, gelida heerka xogta <=4.5Gb/s

 

8

LOS Luminta Tilmaamaha Qaadaha

4

9

RS1 Qiimee xulashada0, si ikhtiyaari ah u maamul gudbiyaha SFP+ Markay sareeyso, heerka gelida xogta>4.5Gb/s; marka ay hooseyso, gelida heerka xogta <=4.5Gb/s

 

10

VeeR Module dhulka qaata

1

11

VeeR Module dhulka qaata

1

12

RD- Xogta la rogay ee qaataha ayaa la saaray

 

13

RD+ Qaadaha xogta aan leexleexnayn oo la saaray

 

14

VeeR Module dhulka qaata

1

15

VccR Soo dhaweynta Module 3.3V

 

16

VccT Module gudbiyaha 3.3V sahayda

 

17

VeeT Dhulka gudbiyaha module

1

18

TD+ Gudbiyaha ayaa xogta rogay

 

19

TD- Gudbiyaha xogta aan leexleexin ayaa la saaray

 

20

VeeT Dhulka gudbiyaha module

1

Fiiro gaar ah:1. biinanka dhulka moduleka waa in laga go'doomiyo kiiska moduleka.
2. biinkan waa biin wax soo saarka ururiyaha/dareenka furan waxaana lagu jiidaa 4.7K-10Kohms ilaa Host_Vcc ee sabuuradda martida loo yahay.
3. biinkan waa in lagu soo jiidaa 4.7K-10Kohms ilaa VccT ee moduleka.
4. biinkan waa biin wax soo saarka ururiyaha/ shubidda furan waxaana lagu soo jiidaa 4.7K-10Kohms ilaa Host_Vcc ee sabuuradda martida loo yahay.

Module SFP EEPROM Macluumaadka iyo Maareynta

Qaybaha SFP waxay hirgeliyaan borotokoolka isgaarsiineed ee 2-fire sida lagu qeexay SFP-8472. Macluumaadka aqoonsiga taxanaha ah ee modules-yada SFP iyo cabbirada Kormeeraha ogaanshaha Dijital ah waxaa laga heli karaa I2Interface-ka C ee ciwaanka A0h iyo A2h. Xusuustu waxay ku taal shaxda 1. Macluumaadka aqoonsiga oo faahfaahsan (A0h) waxay ku taxan tahay shaxda 2iyo tisaga sifaynta DDM ee ciwaanka A2h. Faahfaahin dheeraad ah oo ku saabsan khariidadda xusuusta iyo qeexitaannada byte, fadlan tixraac SFF-8472, "Interface Monitoring Diagnostic Interface for Optical Transceivers". Halbeegyada DDM ayaa gudaha lagu cabbiray.

Shaxda1. Khariidadda xusuusta Dijital ah ee ogaanshaha (Qeexitaannada Goobta Xogta Gaarka ah).

badeecada1

Shaxda 2- EEPROM Aqoonsiga Taxanaha ah ee ku jira xusuusta (A0h)

Cinwaanka Xogta

Dhererka

(Byte)

Magaca

Dhererka

Sharaxaada iyo Nuxurka

Goobaha Aqoonsiga Saldhigga

0

1

Aqoonsiga

Nooca gudbiyaha taxanaha ah (03h=SFP)

1

1

La xafiday

Aqoonsiga fidsan nooca taxanaha ah (04h)

2

1

Xiriiriyaha

Nooca isku xirka indhaha (07=LC)

3-10

8

Transceiver

10G Saldhig-LR

11

1

Codaynta

64B/66B

12

1

BR, Magac ahaan

Heerka baud magac ahaan, halbeegga 100Mbps

13-14

2

La xafiday

(0000h)

15

1

Dhererka (9um)

Dhererka isku xirka ayaa lagu taageeray 9/125um fiber, unugyo 100m ah

16

1

Dhererka (50um)

Dhererka isku xirka ayaa lagu taageeray 50/125um fiber, unugyo 10m ah

17

1

Dhererka (62.5um)

Dhererka isku xirka ayaa lagu taageeray 62.5/125um fiber, unugyo 10m ah

18

1

Dhererka (Naxaasta)

Dhererka isku xirka ayaa lagu taageeray naxaas, halbeeg mitir

19

1

La xafiday

 

20-35

16

Magaca Iibiyaha

Magaca iibiyaha SFP:VIP Fiber

36

1

La xafiday

 

37-39

3

Iibiyaha OUI

Iibiyaha SFP OUI ID

40-55

16

Iibiyaha PN

Lambarka Qaybta: "SFP+ -10G-LR” (ASCII)

56-59

4

Iibiyaha rev

Heerka dib u eegista lambarka qaybta

60-62

3

La xafiday

 

63

1

CCID

Inta ugu yar ee xogta wadarta ciwaanka 0-62
Goobaha aqoonsiga ee la fidiyay

64-65

2

Ikhtiyaarka

Waxay muujinaysaa calaamadaha SFP-ga ee la hirgeliyay

(001Ah = LOS, TX_FAULT, TX_DISABLE dhamaan waa la taageeray)

66

1

BR, ugu badnaan

Margin heerka xoogaa sare, cutubyada %

67

1

BR, min

Xadka heerka yara hooseeya, cutubyada %

68-83

16

Iibiyaha SN

Nambarka taxanaha ah (ASCII)

84-91

8

Koodhka taariikhda

VIP FiberKoodhka taariikhda wax-soo-saarka

92-94

3

La xafiday

 

95

1

CCEX

Hubi koodka meelaha aqoonsiga la fidiyay (cinwaanada 64 ilaa 94)
Goobaha Aqoonsiga Gaarka ah ee Iibiyaha

96-127

32

Wax la akhriyi karo

VIP Fibertaariikh gaar ah, akhri kaliya

128-255

128

La xafiday

U kaydsan SFF-8079

Astaamaha Kormeeraha ogaanshaha Dijital ah

Cinwaanka Xogta

Halbeegga

Saxnaanta

Unug

96-97 Heerkulka Guddaha Transceiver ±3.0 °C
100-101 Eexda Laser Hadda ±10 %
100-101 Awood soo saarista Tx ±3.0 dBm
100-101 Awood Gelitaanka Rx ±3.0 dBm
100-101 Voltage Supply VCC3 Gudaha ±3.0 %

U Hogaansanaanta Nidaaminta

TheSFP+ -10G-LR waxay u hogaansantaa waafaqid Electromagnetic Electromagnetic (EMC) iyo shuruudaha iyo heerarka badbaadada caalamiga ah (eeg faahfaahinta shaxda soo socota).

Dheejinta Electrostatic

(ESD) ilaa biinanka Korontada

MIL-STD-883E

Habka 3015.7

Fasalka 1 (> 1000 V)
Soo saarista Electrostatic (ESD)

Ku soo dhawoow Duplex LC Reception

IEC 61000-4-2

GR-1089-CORE

waafaqsan heerarka
Electromagnetic

Faragelinta (EMI)

FCC Qaybta 15 Fasalka B

EN55022 Heerka B (CISPR 22B)

VCCI fasalka B

waafaqsan heerarka
Badbaadada Isha Laser FDA 21CFR 1040.10 iyo 1040.11

EN60950, EN (IEC) 60825-1,2

La jaan qaadaya heerka 1 laser

alaabta.

Wareegtada lagu taliyay

badeecada4

Wareegga Bixinta Korontada ee Guddiga Martigelinta ee lagu taliyay

badeecada5

Wareegga Interface-xawaare Sare ee lagu taliyay

Cabirka Makaanikada

alaabta2

  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir