MTP/MPO ilaa LC fanout fiber optic patch cable
Waa maxay isku xidhaha MPO?
+ Xadhkaha xadhkaha MTP/MPO, oo sidoo kale loo yaqaan xadhigga jaban ee MTP/MPO ama xadhigga fan-out MTP/MPO, waa xadhig fibre optic ah oo la joojiyey xidhiyeyaasha MTP/MPO ee hal daraf ah iyo isku xidhayaasha MTP/MPO/LC/FC/SC/ST/MTRJ (guud ahaan MTP ilaa LC) ee dhinaca kale. Fiilada ugu weyn ayaa badanaa ah 3.0mm LSZH Fiilo wareeg ah, fiilo 2.0mm ah oo dillaacsan. Xidhiidhiyaha MPO/MTP lab iyo dheddig ayaa diyaar ah, xidhiyaha nooca labguna waxa uu leeyahay biinanka.
+ AnMPO-LC fiilada jabanwaa nooc ka mid ah fiilada fiber optic-ga oo ka gudubta isku xidhka cufnaanta sare ee MTP MPO ee gees ka mid ah xirayaasha LC badan oo dhinaca kale ah. Naqshadeyntani waxay u oggolaaneysaa isku xirnaan hufan oo u dhexeeya kaabayaasha laf dhabarta iyo aaladaha shabakadaha shaqsiyeed.
+ Waxaan bixin karnaa hal qaab iyo Multimode MTP fiber optic patch fiilooyin, naqshadaynta caadada MTP fiber optic shirarka fiilooyinka, qaab kali ah, Multimode OM1, OM2, OM3, OM4, OM5. Waxaa lagu heli karaa 8 koofiyadaha, 12core MTP/MPO fiilooyinka balastar, 24core MTP/MPO fiilooyinka balastar, 48core MTP/MPO fiilooyinka balastar ah.
Codsiyada
+ Xarumaha Xogta Sarreysa: Xarumaha xogta cabbirka sare waxay ku tiirsan yihiin xalalka fiilooyinka cufnaanta sare si ay u maareeyaan culeyska xogta ballaaran. Xadhkaha goosashada MPO-LC waxay ku habboon yihiin isku xirka server-yada, furayaasha, iyo router-yada ee leh daahitaanka ugu yar.
+ Isgaarsiinta: Soo-bandhigista shabakadaha 5G waxay si weyn ugu xiran tahay kaabayaasha fiber optic-ga ee la isku halayn karo. Xadhkaha goos gooska MPO-LC waxay xaqiijiyaan isku xidhka aan kala go'a lahayn ee codsiyada isgaadhsiinta.
+ AI iyo Nidaamyada IoT: Nidaamyada AI iyo IoT waxay u baahan yihiin socodsiinta xogta waqtiga-dhabta ah. Xadhkaha goos gooska MPO-LC waxay bixiyaan daahitaanka aadka u hooseeya iyo baaxadda baaxadda sare ee looga baahan yahay tignoolajiyadan-goynta.
Tilmaamaha
| Nooca | Qaab kali ah | Qaab kali ah | Qaababka badan | |||
|
| (APC Polish) | (UPC Polish) | (PC Polish) | |||
| Tirada Fiber | 8,12,24 iwm. | 8,12,24 iwm. | 8,12,24 iwm. | |||
| Nooca Fiber | G652D,G657A1 iwm. | G652D,G657A1 iwm. | OM1,OM2,OM3, OM4, iwm. | |||
| Max. Gelida Khasaare | Elite | Heerka | Elite | Heerka | Elite | Heerka |
|
| Khasaare hooseeya |
| Khasaare hooseeya |
| Khasaare hooseeya |
|
|
| ≤0.35 dB | ≤0.75dB | ≤0.35 dB | ≤0.75dB | ≤0.35 dB | ≤0.60dB |
| Soo Celinta Khasaaraha | ≥60 dB | ≥60 dB | NA | |||
| Waarta | ≥500 jeer | ≥500 jeer | ≥500 jeer | |||
| Heerkulka shaqada | -40 ℃ ~ + 80 ℃ | -40 ℃ ~ + 80 ℃ | -40 ℃ ~ + 80 ℃ | |||
| Tijaabi hirarka dhererka | 1310nm | 1310nm | 1310nm | |||
| Geli-jiid imtixaanka | 1000 jeer 0.5 dB | |||||
| Isdhaafsiga | 20.5 dB | |||||
| Xoogaga ka hortagga | 15kgf | |||||