Bogga calanka

KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40km Transceiver

Sharaxaad Gaaban:

KCO SFP+ 10G ER waa halbeeg loogu talagalay 10 Gigabit Ethernet oo ka sarreeya fiilooyinka fiber optic, gaar ahaan loogu talagalay gudbinta fogaanta.

Waxa ay u ogolaataa in xogta la wareejiyo ilaa 40 km in ka badan hal-mode fiber (SMF) oo dhererkeedu yahay 1550nm.

KCO SFP+ 10G ER modules fiber optic, oo inta badan loo hirgaliyo SFP+ transceivers, ayaa loo adeegsadaa codsiyo kala duwan halka loo baahan yahay gaadhista la fidinayo, sida isku xidhka dhismayaasha ku yaala dhismo wayn ama gudaha isku xidhka aaga magaaloyinka.


Faahfaahinta Alaabta

Tags Product

KCO-SFP+-10G-ER

+ KCO SFP+ 10G ER waa halbeeg loogu talagalay 10 Gigabit Ethernet oo ka sarreeya fiilooyinka fiber optic, si gaar ah loogu talagalay gudbinta fogaanta.

+ Waxay u ogolaataa wareejinta xogta ilaa 40 km in ka badan hal qaab fiber (SMF) oo dhererkeedu yahay 1550nm.

+KCO SFP+ 10G ER modules fiber optic, oo inta badan loo hirgaliyo SFP+ transceivers, ayaa loo adeegsadaa codsiyo kala duwan halka loo baahan yahay in la fidiyo, sida isku xidhka dhismooyinka ku yaal xarun weyn ama gudaha isku xidhka aagga magaalo-madaxda.

Tilmaamaha Alaabta

+ Ilaa 11.1Gbps Data Links

+ Ilaa 40km gudbinta SMF

+ gudbiyaha EML iyo PIN qaataha

+ Xero bir ah, oo loogu talagalay EMI hoose

+ 2-silig interface oo leh kormeerka ogaanshaha dhijitaalka ah ee isku dhafan

+ Raad-raac kulul oo lagu dhejin karo SFP

+ Tilmaamo waafaqsan SFF 8472

+ U hoggaansan SFP+ MSA oo leh xiriiriyaha LC

+ Keliya koronto 3.3V

+ Heerkulka shaqada ee kiiska:0°C ilaa 70°C

+ Quwadda Korontada <1.5 W

Codsiyada

+ 10GBASE-ER/EW & 10G Ethernet

Heerka

+ U hoggaansan SFF-8431

+ U hoggaansan SFF 8472

+ RoHS waafaqsan.

Qiimaynta ugu Sarreysa

Halbeegga

Astaanta

Min.

Nooca

Max.

Unug

Heerkulka Kaydinta

Ts

-40

-

85

ºC

Qoyaanka Qaraabada

RH

5

-

95

%

Korontada Supply

VCC

-0.3

-

4

V

Korontada Gelitaanka Signal

Vcc-0.3

-

Vcc+0.3

V

Shuruudaha Hawleed ee lagu taliyay

Halbeegga

Astaanta

Min.

Nooca

Max.

Unug

Ogow

Heerkulka Hawlgelinta Kiis

Tkiis

0

-

70

ºC

Hawo la'aan

Korontada Supply

VCC

3.14

3.3

3.47

V

Bixinta Korontada hadda

ICC

-

450

mA

Heerka Xogta

BR

10.3125

Gbps

Fogaanta Gudbinta

TD

-

40

km

Fiber la isku daray

Hal qaab fiber

9/125um SMF

Tilmaamaha indhaha

Halbeegga

Astaanta

Min.

Nooca

Max.

Unug

Ogow

Gudbiye

Celceliska Awoodda La Bilaabay

PO

-1

+3

dBm

Xusuusin (1)

Saamiga Dabar goynta

ER

6

dB

Hirarka dhexda

λc

1530

1550

1565

nm

Balaadhka Xajmiga Spectrum (RMS)

σ

1.0

nm

SMSR

30

dB

Gudbiyaha Demin Awoodda Soo-saarka

Poff

-30

dBm

Ciqaabta Gudbinta iyo Kala-firdhinta

TDP

3.0

dB

Maaskarada Indhaha

Waafaqsan IEEE 802.3ae

qaataha

Gelida Mawjada Aragga

λ

1270

1610

nm

Dareenka qaataha

Psen

-15.8

dBm

Xusuusin (2)

Qulqulka Qulqulka Gelida (kordhinta)

Psat

0.5

dBm

LOS Detect - Awood sheeg

PA

-28

dBm

LOS Detect - Awoodda macmacaan

PD

-19

dBm

LOS Ogow Hysteresis

FIISKA

0.5

dB

Fiiro gaar ah:
1.Launched Power (Vg.) waa koronto lagu daray hal qaab fiber oo leh xiriiriyaha sare. (Nolosha ka hor)
2. Lagu cabbiray calaamada tijaabada waafaqsanaanta BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Tilmaamaha Korontada

Halbeegga

Astaanta

Min

Nooca

Max

Unug

FIIRO GAAR AH

Supply Voltage

Vcc

3.14

3.3

3.46

V

Bixinta Hadda

Icc

450

mA

Gudbiye

Gelida carqaladaynta kala duwanaanta

Rin

100

Ω

1

Gelida xogta kelida dhammaatay

Vin, pp

180

700

mV

Gudbi Disable Voltage

VD

Vcc–1.3

Vcc

V

Gudbi Awood Korantada

VEN

Vee

Vee+ 0.8

V

2

Gudbi Disable Time Assert

10

us

qaataha

Kala duwanaanshaha soo saarista xogta

Cod, pp

300

850

mV

3

Wakhtiga kor u kaca soo-saarka xogta

tr

28

ps

4

Waqtiga dayrta soo saarista xogta

tf

28

ps

4

Khaladka LOS

Cilada VLOS

Vcc–1.3

VccHOST

V

5

LOS Caadi

VLOS caadiga ah

Vee

Vee+0.8

V

5

Diidmada Awood-siinta

PSR

100

mVpp

6

Xusuusin:

  1. Si toos ah ugu xidhan biinanka gelinta xogta TX. AC oo la isku daray ka dib.
  2. Ama wareeg furan.
  3. Gelida 100 ohms joojinta kala duwanaanshaha.
  4. 20 - 80%.
  5. Luminta calaamaduhu waa LVTTL. Logic 0 wuxuu muujinayaa hawlgal caadi ah; macquulka 1 ayaa tilmaamaya in aan calaamad la ogaan.

Dareenka qaataha wuxuu u hoggaansamaa qaab-dhismeedka sinusoidal sahayda korantada oo ah 20 Hz ilaa 1.5 MHz ilaa qiime cayiman oo lagu dabaqo shabakadda shaandhaynta saadka korontada ee lagu taliyay.

Sharaxaada Pin

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40km Transceiver (1)

Pin

Astaanta

Magaca/Sharaxaada

FIIRO GAAR AH

1

VEET

Ground Gudbiyaha (Caadi ah oo leh Goolka qaataha)

1

2

TKHALAD

Khaladka Gudbinta.

2

3

TDIS

Daarmi gudbiyaha Soo saarista laser-ka ayaa naafo ah kor ama furan

3

4

SDA

2-xadhka xogta Interface Serial Serial

4

5

SCL

2-fiil Serial Interface Clock Line

4

6

MOD_ABS

Module Maqan Ku salaysan moduleka

4

7

RS0

Qiimaha Xulashada 0

5

8

LOS

Luminta calaamadda calaamadda. Macquul 0 waxa ay tilmaamaysaa hawlgal caadi ah.

6

9

RS1

Xiriir uma baahna

1

10

VEER

Dhulka Qaadka (Caadi ah oo leh Goolka Gudbinta)

1

11

VEER

Dhulka Qaadka (Caadi ah oo leh Goolka Gudbinta)

1

12

RD-

Qaataha DATA rogay. AC oo isku xidhan

13

RD+

Qaataha DATA Aan leexleexad lahayn. AC oo isku xidhan

14

VEER

Dhulka Qaadka (Caadi ah oo leh Goolka Gudbinta)

1

15

VCCR

Qalabka Korontada qaataha

16

VCCT

Korontada Gudbinta

17

VEET

Ground Gudbiyaha (Caadi ah oo leh Goolka qaataha)

1

18

TD+

Gudbiyaha Xogta Aan Roganayn ee AC.

19

TD-

Gudbiyaha u rogay DATA gudaha AC

20

VEET

Ground Gudbiyaha (Caadi ah oo leh Goolka qaataha)

1

Xusuusin:

  1. Dhulka wareegga waa ka go'doonsan dhulka chassis.
  2. TKHALADwaa wax soo saarka ururiyaha/shubanka furan, kaas oo ay tahay in lagu soo jiido 4.7k - 10k Ohms iska caabiyaha guddiga martida loo yahay haddii loogu talagalay in la isticmaalo. Korantada soo jiidashada waa in ay ahaataa inta u dhaxaysa 2.0V ilaa Vcc + 0.3VA wax soo saarka sare waxa ay tusinaysaa cilada gudbiyaha ee ay keentay labada eexda TX ama awooda wax soo saarka TX oo ka badan heeryada alaarmiga ee hore loo dejiyay. Wax soo saar hoose ayaa tilmaamaya hawlgal caadi ah. Xaaladda hoose, wax soo saarka waxaa loo jiidaa <0.8V.
  3. Soo saarista laser-ka waa la joojiyay TDIS>2.0V ama furan, karti u leh TDIS<0.8V
  4. Waa in lagu soo qaadaa 4.7kΩ- ​​10kΩ guddiga martida loo yahay oo lagu kordhinayo danab u dhexeeya 2.0V iyo 3.6V. MOD_ABS waxa ay jiidataa xariiqda hoose si ay u muujiso in cutubku xidhan yahay.
  5. Gudaha hoos ayaa loo dhigay SFF-8431 Rev 4.1.
  6. LOS waa wax soo saarka ururiyaha furan. Waa in lagu soo qaadaa 4.7kΩ – 10kΩ oo saaran sabuuradda martida loo yahay ilaa 2.0V iyo 3.6V. Logic 0 wuxuu muujinayaa hawlgal caadi ah; macquulka 1 wuxuu muujinayaa luminta calaamadda.

Hawlaha ogaanshaha Dijital ah

Transceivers OP-SFP+-ER waxay taageeraan borotokoolka isgaarsiineed ee 2-fire sida lagu qeexay SFP+MSA.

Aqoonsiga taxanaha caadiga ah ee SFP waxa uu bixiyaa marin u helka macluumaadka aqoonsiga ee qeexaya awoodaha gudbiyaha, isku xidhka caadiga ah, soo saaraha, iyo macluumaadka kale.

Intaa waxaa dheer, SFP+ transceivers waxay bixiyaan interface la socodka ogaanshaha dhijitaalka ah oo la xoojiyey oo gaar ah, kaas oo u oggolaanaya gelitaanka-waqtiga-dhabta ah ee cabbirrada qalabka sida heerkulka transceiver, eexda laysarka hadda, awoodda indhaha ee la kala qaado, la helay awoodda indhaha iyo koronta sahayda gudbiyaha. Waxa kale oo ay qeexdaa nidaam casri ah oo digniinta digniinta iyo digniinta ah, kaas oo u digay isticmaalayaasha dhamaadka marka cabbirada hawlgalka gaarka ah ay ka baxsan yihiin warshadda dejisay xadka caadiga ah.

SFP MSA waxay qeexaysaa khariidadda xusuusta 256-byte ee EEPROM taas oo laga heli karo in ka badan 2-fire interface interface ee 8-bit ciwaanka 1010000X (A0h) .Interface kormeerka ogaanshaha dhijitaalka ah ayaa isticmaalaya ciwaanka 8-bit 1010001X (A2h), sidaas darteed khariidadda aqoonsiga serial ee asal ahaan aan la bedelin xusuusta.

Macluumaadka hawlgalka iyo ogaanshaha waxa la socda oo ay soo sheegaan Digital Diagnostics Transceiver Controller (DDTC) gudaha transceiver-ka, kaas oo laga galo isku xidhka 2-siliga ah. Marka borotokoolka taxanaha ah la hawlgeliyo, calaamada saacada taxanaha ah (SCL, Mod Def 1) waxaa soo saaray martigeliyaha. Cidhifka togan ayaa ku xidhaya xogta gudbiyaha SFP qaybahaas E2PROM ee aan qor-ilaalin. Cidhifka taban ayaa saacadaha xogta ka soo gudbiya SFP. Calaamadda xogta taxanaha ah (SDA, Mod Def 2) waa laba jiho wareejinta xogta taxanaha ah. Martigeliyaha wuxuu isticmaalaa SDA isagoo la kaashanaya SCL si uu u calaamadiyo bilawga iyo dhammaadka hawlgelinta borotokoolka taxanaha ah. Xusuusaha waxaa loo habeeyey si taxane ah oo 8-bit ah kelmado xog ah oo si gaar ah ama si isdaba joog ah wax looga qaban karo.

Wareegga Interface ee lagu taliyay

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40km Transceiver (2)

Tilmaanta Cabbirrada

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40km Transceiver (3)

U Hogaansanaanta Nidaaminta

Muuqaal

Tixraac

Waxqabadka

Dheecaan elektrostatic ah (ESD)

IEC/EN 61000-4-2

waafaqsan heerarka

Faragelinta Electromagnetic (EMI)

FCC Qaybta 15 Fasalka B EN 55022 Fasalka B (CISPR 22A)

waafaqsan heerarka

Badbaadada Isha Laser

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Alaabta 1-aad ee laysarka

ROHS

2002/95/EC

waafaqsan heerarka

EMC

EN61000-3

waafaqsan heerarka

Lifaaqa A. Dib u Eegista Dukumentiga

Nooca No.

Taariikhda

Sharaxaada

1.0

2010-09-01

Xaashida xogta hordhaca ah

2.0

2011-09-10

Cusbooneysii qaabka iyo astaanta shirkadda

3.0

2012-08-03

Cusbooneysii faahfaahinta awoodda -1 ~ 4 ilaa -1 ~ 3


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir