KCO-Fiver-MTP-MPO-QSFP-Banner-bogga-1

8F 12F 24F Multimode OM4 Midabka buluugga ah ee MTP isku xidhka fiilada indhaha ee MPO adapter-ka fiilada

Sharaxaad Gaaban:

+ Nooca adabtarada: adabtarada MPO / adabtarada MTP

+ Adapter fiiqan: SC fiiqan (dekedda adapter simplex ee SC)

+ Midabka: Fiilada / Casaanka

+ Flange: oo leh flange

+ Ku habboon: fiilada jirridda MPO ee OM4, fiilada balastar MTP ee OM4

+ IL: 0.15dB

+ Codsiga:

Module MPO, module MTP

guddi balastar MPO ah, guddi balastar MTP ah

+ Tijaabo warshadeed 100% ka hor inta aan la dhoofin.

+ MOQ: 1 xabbo

+ Waqtiga gaarsiinta: 1 maalin


  • Qiimaha FOB:US $0.5 - 9,999 / Qayb
  • Tirada Dalabka Ugu Yar:100 Xabbo/Xabsi
  • Awoodda Bixinta:10000 Xabbo/Xabbadood bishiiba
  • Faahfaahinta Badeecada

    Calaamadaha Alaabta

    Qalabka isku xidhka fiber-ka indhaha ee MTP / adabtarada fiber-ka MPO Sharaxaadda

    + Isku-xidhka fiber-ka indhaha ee MTP / adapter-ka fiber-ka MPO waa isku-xirka loo isticmaalo in lagu xiro fiilada jirridda dheddigga ee MPO iyo fiilada jirridda labka ah ee MPO, waxa kale oo loo adeegsadaa in lagu xiro fiilada jirridda dheddigga ee MPO iyo module-ka labka ah ee MPO (module-ka labka ah ee MPO ilaa LC).

    + Waxaa loo isticmaalaa isku xirka MPO-8, MPO-12, MPO-16, MPO-24, MPO-32, MPO-48.

    + Qalabka isku xidhka fiilada indhaha ee MTP / adabtarada fiilada MPO ee loo isticmaalo guddiga balastar cufnaanta sare ee MPO iyo sanduuqa FTTA ee shaqooyinka badan leh.

    + Isku-xidhka fiilada indhaha ee MTP / adabtarada fiilada MPO waxay leeyihiin 2 nooc:

    Nooca iska soo horjeeda (Furaha ilaa Furaha Hoos): Jillaabka sare ee hal dhinac ayaa ka soo rogmanaya dhinaca kale. Kani waa nooca caadiga ah ee A.

    Nooca la isku waafajiyay (Furaha ilaa Furaha kor): Jillaabku wuxuu ku sii jiraa labada dhinacba. Tan waxaa loo isticmaalaa shabakadaha Nooca B.

    + Qalabka isku xidhka fiber-ka indhaha ee MTP / adapter-ka MPO wuxuu la socdaa flange, si fiican ayuu ugu hagaajin karaa adapter-ka saxanka guddiga balastar-ka.

    + Isticmaalka isku xidhka fiilada indhaha ee MTP / adabtarada fiilada MPO:

    isku xirka mpo-ku-jira-xarunta xogta-baakadda-guddi-1024x683

    Tilmaamaha

    Nooca Isku-xirka MPO/MTP Qaabka Jirka Simplex
    Habka Faybarka Qaab-badanQaab-keli ah Midabka Jirka Qaab hal-hal ah UPC: madowHabka hal-geeska ah ee APC: cagaar

    Qaab badan: madow

    OM3: biyo

    OM4: buluug

    Lumista Gelinta ≤0.15dB Waarta guurka 500 jeer
    Flange Iyada oo leh flangeIyada oo aan lahayn flange Jihaynta Muhiimka ah La isku toosiyay (Furaha kor - Furaha kor)
    Shaashad-shaashadda_2026-05-25_165023_300

    Codsiyada

    + Module MPO / Module MTP

    + Guddi balastar cufnaan sare leh oo MPO ah / guddi balastar cufnaan MTP ah

    + Qalabka Tijaabada

    + Aaladda gudbinta xogta xawaaraha sare leh

    + Xarunta xogta daruuraha I

    + Xarunta xogta isgaarsiinta

    + FTTA bannaanka sanduuqa hawlo badan

    + Fiilooyinka Dhabarka ee Xarunta Xogta

    + AI & Xisaabinta Waxqabadka Sare (HPC)

    + Xalalka MPO ee Breakout & Fan-Out

    + Isgaarsiinta fiber optic-ga ee dadban

    + Nidaamka shabakadda ganacsiga

     

    Astaamaha

    Waxay taageertaa xawaaraha ilaa 40 GbE/100 GbE.

    Xidhiidhiyaha riix/jiid ayaa hal gacan ku rakibaya/ka saaraya.

     Xidhiidhiyayaasha 8, 12, 16, 24, 32, 48-fibers MTP/MPO.

    Hab keli ah iyo Multimode ayaa diyaar ah.

    Saxnaan cabbir sare leh.

    Xiriir degdeg ah oo fudud.

    Guryo balaastig ah oo fudud oo waara.

    Naqshadaynta isku xidhka hal-xabbo waxay kordhisaa xoogga isku xidhka iyadoo la yaraynayo soo saarista qashinka.

    Midabka biyaha, violet-ka ayaa la dooran karaa.

    Dharka sare ee la xiran karo.

    Ku celcelin wanaagsan.


    Codsiga deegaanka:

    Heerkulka hawlgalka

    -20°C ilaa 70°C

    Heerkulka kaydinta

    -40°C ilaa 85°C

    Qoyaanka

    95%RH


  • Kii hore:
  • Xiga:

  • Halkan ku qor fariintaada oo noo soo dir